Basit öğe kaydını göster

dc.contributor.authorCelik, Husey E.
dc.contributor.authorEsin, A. Ilker
dc.contributor.authorSengonul, Kamil
dc.date.accessioned2021-03-03T08:15:58Z
dc.date.available2021-03-03T08:15:58Z
dc.date.issued2019
dc.identifier.citationCelik H. E. , Sengonul K., Esin A. I. , "Evaluation of Irrigation Systems and some Pitch Properties of Selected Football Fields in Istanbul", IRRIGATION AND DRAINAGE, cilt.68, sa.2, ss.332-341, 2019
dc.identifier.issn1531-0353
dc.identifier.otherav_169b0993-9462-44a0-8e75-c9cdbbfcd1bf
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/20525
dc.identifier.urihttps://doi.org/10.1002/ird.2312
dc.description.abstractFootball fields composed of natural grass must maintain a playable state throughout the season. Substructure problems such as inadequacies in drainage and irrigation systems may adversely affect a player's health and game quality in rainy and/or dry seasons. The scope of the study encompasses eight football fields, which have natural turf combined with semi- or fully automatic sprinkler systems, with permission given for study in Istanbul. Irrigation systems, infiltration rate, surface hardness, turf coverage and root penetration parameters were investigated on these playing fields. The results were evaluated according to FIFA, UEFA, TFF and other national and international standards. Our findings showed that none of the sprinkler systems of these football fields could meet the minimum Christiansen's coefficient of uniformity ratio (84%). Only one of the sprinkler systems of the stadiums had a fair rating according to a distribution uniformity ratio. All fields, except for one, had low (<100 mm h(-1)) infiltration rates for first-class grounds. Cover percentages of the lawns were at desirable levels except for one stadium, which had excessive weed problems. Generally, root depths (<15 cm) and plant densities (5-15) were poor in the fields. Surface hardness was high (107 G-max) in one stadium, normal in another stadium (72 G-max) and low (< 70 G-max) in the rest. (c) 2019 John Wiley & Sons, Ltd.
dc.language.isoeng
dc.subjectToprak ve Su Muhafazası ve Amenajmanı
dc.subjectHavza Yönetimi
dc.subjectToprak Verimliliği ve Gübreleme
dc.subjectTarımsal Bilimler
dc.subjectToprak ve Bitki Besleme
dc.subjectZiraat
dc.subjectÇevre / Ekoloji
dc.subjectSU KAYNAKLARI
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectTarım Bilimleri
dc.subjectTARIM BİLİMİ
dc.titleEvaluation of Irrigation Systems and some Pitch Properties of Selected Football Fields in Istanbul
dc.typeMakale
dc.relation.journalIRRIGATION AND DRAINAGE
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume68
dc.identifier.issue2
dc.identifier.startpage332
dc.identifier.endpage341
dc.contributor.firstauthorID263649


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster