Show simple item record

dc.contributor.authorKatiboglu, A. B.
dc.contributor.authorLewandowska, M.
dc.contributor.authorBulutsuz, A. G.
dc.contributor.authorMercan, C. U.
dc.contributor.authorKarapinar, G.
dc.date.accessioned2021-03-03T08:13:38Z
dc.date.available2021-03-03T08:13:38Z
dc.date.issued2016
dc.identifier.citationBulutsuz A. G. , Mercan C. U. , Karapinar G., Katiboglu A. B. , Lewandowska M., "Influence of Surface Modification Methods on the Topography of Dental Implants by Using Metrological Observation Techniques", ACTA PHYSICA POLONICA A, cilt.129, sa.4, ss.625-627, 2016
dc.identifier.issn0587-4246
dc.identifier.otherav_1660bccd-c9a8-4d31-8986-2a01e6549d34
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/20375
dc.identifier.urihttps://doi.org/10.12693/aphyspola.129.625
dc.description.abstractOver the last few decades the use of dental implants has been increasing everyday as a solution for partial or full edentulism. The osseointegration process has to be fully completed to reach a prosthetic phase, so that patient can start to use the dental implants functionally. One of the most important factors affecting osseointegration is the surface properties of dental implants. Surface roughness of dental implant is vital to increase bone anchoring and maintain the biomechanical stability. In addition to successful application of dental implants, rapid osseointegration has also been desired as a favorable situation. It is demonstrated that there is a strong correlation between the successful application and rapid osseointegration of dental implants and the surface morphology and characteristics of dental implants. From this point of view, investigation of the surface morphology of implants has a vital importance for manufacturers. The aim of our study was to evaluate the surface topography and homogeneity of dental implants with different surface modifications by means of 2D and 3D observation methods.
dc.language.isoeng
dc.subjectTemel Bilimler (SCI)
dc.subjectTemel Bilimler
dc.subjectFİZİK, MULTİDİSİPLİNER
dc.subjectFizik
dc.subjectDisiplinlerarası Fizik ve İlgili Bilim ve Teknoloji Alanları
dc.titleInfluence of Surface Modification Methods on the Topography of Dental Implants by Using Metrological Observation Techniques
dc.typeMakale
dc.relation.journalACTA PHYSICA POLONICA A
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume129
dc.identifier.issue4
dc.identifier.startpage625
dc.identifier.endpage627
dc.contributor.firstauthorID231750


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record