Show simple item record

dc.contributor.authorBud, Marius
dc.contributor.authorSancakli, Hande Sar
dc.contributor.authorKukey, Pelin
dc.contributor.authorKORKUT, BORA
dc.date.accessioned2023-02-21T10:15:18Z
dc.date.available2023-02-21T10:15:18Z
dc.date.issued2022
dc.identifier.citationKORKUT B., Bud M., Kukey P., Sancakli H. S., "Effect of surface sealants on color stability of different resin composites", Medicine and Pharmacy Reports, cilt.95, sa.1, ss.71-79, 2022
dc.identifier.issn2602-0807
dc.identifier.othervv_1032021
dc.identifier.otherav_3fc8e36f-7769-4a4d-9119-0c4a3187cf6f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/188238
dc.identifier.urihttps://avesis.istanbul.edu.tr/api/publication/3fc8e36f-7769-4a4d-9119-0c4a3187cf6f/file
dc.identifier.urihttps://doi.org/10.15386/mpr-1973
dc.description.abstract© 2022Objective. The aim was to assess the effect of surface sealants on the color stability of different composite materials. Methodology. 120 samples were prepared using Filtek Ultimate (3M, USA), Charisma Topaz (Kulzer, Germany), and Clearfil Majesty Es-2 Premium (Kuraray Noritake, Japan) composites. The samples were polished with polishing discs and divided by test groups (n=10 for each), regarding the sealant used; Permaseal (Ultradent Products, USA), Biscover LV (Bisco, USA), Optiglaze Clear (GC Corp., Japan) and control. The samples were discolored for 144 hours in coffee solution at constant 37ºC, renewing daily. Color measurements were performed at the baseline, following the sealant application, and after discoloration procedure, using a spectrophotometer (EasyShade 5, Vita-Zahnfabrik, Germany). The collected L*C*h* coordinates were converted to corresponding L*a*b* coordinates and the color changes (∆E) were calculated. Results. All the sealants presented perceptible (>1.2) and unacceptable (>2.7) color changes. Biscover LV presented the lowest ∆E among all sealants (p<0.001). The highest ∆E was observed for Permaseal (p<0.001). Color changes for Optiglaze and control groups were similar (p≥0.05). Filtek Ultimate presented the highest color stability (p<0.001), followed by Charisma Topaz and Clearfil Majesty. The combination of Filtek Ultimate with Biscover LV was considered to have the highest color stability, whereas the combination of Clearfil Majesty with Permaseal was considered the lowest, among all. Conclusion. Experimented sealants were considered relatively effective on color stability of resin composites depending on the type of the sealant and the composite material. However, the use of surface sealants may not be advantageous every time. Biscover LV have inhibited the level of discoloration, whereas Permaseal had an increasing effect generally.
dc.language.isoeng
dc.subjectKlinik Tıp
dc.subjectGenel Tıp
dc.subjectTemel Tıp Bilimleri
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectTIP, GENEL & DAHİLİ
dc.titleEffect of surface sealants on color stability of different resin composites
dc.typeMakale
dc.relation.journalMedicine and Pharmacy Reports
dc.contributor.departmentMarmara Üniversitesi , Diş Hekimliği Fakültesi , Diş Hekimliği Klinik Bilimleri Bölümü
dc.identifier.volume95
dc.identifier.issue1
dc.identifier.startpage71
dc.identifier.endpage79
dc.contributor.firstauthorID4227642


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record