Show simple item record

dc.contributor.authorGöktaş, Halime Ceren
dc.contributor.authorEngiz, Gizem
dc.contributor.authorSu, Esra
dc.contributor.authorGömeç, Çiğdem
dc.date.accessioned2022-07-04T16:17:25Z
dc.date.available2022-07-04T16:17:25Z
dc.identifier.citationGöktaş H. C. , Engiz G., Su E., Gömeç Ç., "Comparative evaluation of biogas recovery during anaerobic treatment of aircraft deicing fluids at increased ratios in domestic wastewater", DESALINATION AND WATER TREATMENT, cilt.172, ss.254-259, 2019
dc.identifier.issn1944-3994
dc.identifier.othervv_1032021
dc.identifier.otherav_dd346be6-69b3-4921-aefa-d3d718a99073
dc.identifier.urihttp://hdl.handle.net/20.500.12627/184985
dc.identifier.urihttps://doi.org/10.5004/dwt.2019.24976
dc.description.abstractIn this study, anaerobic treatability of domestic wastewater contaminated with two different types of aircraft deicing fluids (ADFs) at different ratios (i.e., Type 1: 0.9%-9.7% and Type 2: 1.8%-12.5%) were comparatively investigated with the control reactors using batch systems operated at mesophilic temperature (35 degrees C). In this respect, the threshold Type 1_ and Type 2_ADF ratios indicated inhibition on the microbial cultures were determined according to the biogas yields during the incubation time. The highest biogas yields were calculated as about 0.22 and 0.25 m(3)/kg tCOD(fed) in the bioreactors having 0.9% Type 1_ADF and 1.8% Type 2_ADF, respectively. However, when tCOD removals were also taken into account; 3.4% Type 1_ADF and 1.8% Type 2_ADF represented the upper concentration limits excluding the control reactors. Because the reactors with more than 3.5% Type 1_ADF and 2.0% Type 2_ADF indicated significant inhibition on microbial cultures with considerable reductions in biogas yields and organic material removals. Hence, ADF-contaminated wastewaters are of great concern for anaerobic reactors that require careful control at full-scale treatment facilities.
dc.language.isoeng
dc.subjectMühendislik
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectSU KAYNAKLARI
dc.subjectÇevre / Ekoloji
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectToprak ve Bitki Besleme
dc.subjectZiraat
dc.subjectTarımsal Bilimler
dc.subjectToprak ve Su Muhafazası ve Amenajmanı
dc.subjectHavza Yönetimi
dc.subjectKimya Mühendisliği ve Teknolojisi
dc.subjectMühendislik ve Teknoloji
dc.subjectGeneral Engineering
dc.subjectWater Science and Technology
dc.subjectChemical Health and Safety
dc.subjectFluid Flow and Transfer Processes
dc.subjectChemical Engineering (miscellaneous)
dc.subjectEngineering (miscellaneous)
dc.subjectGeneral Chemical Engineering
dc.subjectColloid and Surface Chemistry
dc.subjectCatalysis
dc.subjectPhysical Sciences
dc.subjectMÜHENDİSLİK, KİMYASAL
dc.titleComparative evaluation of biogas recovery during anaerobic treatment of aircraft deicing fluids at increased ratios in domestic wastewater
dc.typeMakale
dc.relation.journalDESALINATION AND WATER TREATMENT
dc.contributor.departmentİstanbul Teknik Üniversitesi , Yabancı Diller Yüksekokulu ,
dc.identifier.volume172
dc.identifier.startpage254
dc.identifier.endpage259
dc.contributor.firstauthorID3424948


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record