dc.date.available | 2022-02-18T11:30:48Z | |
dc.identifier.citation | Mainardi L., Petrucci E., Balian V., Bianchi A., Porta A., Canziani R., Cerutti S., "Time-variant heart-rate variability spectral parameters during dobutamine test", 25th Annual Meeting on Computers in Cardiology, Ohio, Amerika Birleşik Devletleri, 13 - 16 Eylül 1998, cilt.25, ss.105-108 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_ffd8f408-4fba-433d-bd28-b86b7065c882 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/181340 | |
dc.identifier.uri | https://doi.org/10.1109/cic.1998.731738 | |
dc.description.abstract | In this paper time-variant spectral parameters are used to monitor the Autonomic Nervous System (ANS) status in normal and coronary artery disease (CAD) patients during pharmacological infusion of Dobutamine in Dobutamine Echocardiography Test (DET). During the test, the spectral parameters (LF and HF power, LF/HF ratio) are estimated on a beat-to-beat bases through the time-variant identification of an AutoRegressive (AR) model, using a Recursive Least Square (RLS) algorithm. Different LF responses have been found in the early stages of drug infusion (10-20 gamma) sequentially before the appearance of echo, ECG or clinical signs of ischemia. An early increase of LF/LFbasal value was found in 6 of 8 (75%) positive tests, and only in 2 of 9 (22%) negative ones, suggesting that the different neurovegetative response in the sub-maximal stages of drug infusion may be a marker of an actual or successive ischemia. | |
dc.language.iso | eng | |
dc.subject | Fizyoloji | |
dc.subject | Dahili Tıp Bilimleri | |
dc.subject | Kardiyoloji | |
dc.subject | Nükleer Tıp | |
dc.subject | Biyomedikal Mühendisliği | |
dc.subject | Yaşam Bilimleri | |
dc.subject | Temel Bilimler | |
dc.subject | Mühendislik ve Teknoloji | |
dc.subject | Physiology | |
dc.subject | General Engineering | |
dc.subject | Engineering (miscellaneous) | |
dc.subject | Biomedical Engineering | |
dc.subject | Bioengineering | |
dc.subject | Physiology (medical) | |
dc.subject | Radiology, Nuclear Medicine and Imaging | |
dc.subject | Medical Laboratory Technology | |
dc.subject | Health Informatics | |
dc.subject | Biochemistry (medical) | |
dc.subject | Cardiology and Cardiovascular Medicine | |
dc.subject | Physical Sciences | |
dc.subject | Life Sciences | |
dc.subject | Health Sciences | |
dc.subject | Radiological and Ultrasound Technology | |
dc.subject | CARDIAC ve CARDIOVASCULAR SİSTEMLER | |
dc.subject | Klinik Tıp | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | MÜHENDİSLİK, BİYOMEDİKSEL | |
dc.subject | Mühendislik | |
dc.subject | Mühendislik, Bilişim ve Teknoloji (ENG) | |
dc.subject | TIBBİ BİLİŞİM | |
dc.subject | TIBBİ LABORATUVAR TEKNOLOJİSİ | |
dc.subject | FİZYOLOJİ | |
dc.subject | Biyoloji ve Biyokimya | |
dc.subject | Yaşam Bilimleri (LIFE) | |
dc.subject | RADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME | |
dc.subject | Tıp | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Temel Tıp Bilimleri | |
dc.subject | Biyoistatistik ve Tıp Bilişimi | |
dc.subject | Biyokimya | |
dc.title | Time-variant heart-rate variability spectral parameters during dobutamine test | |
dc.type | Bildiri | |
dc.contributor.department | , , | |
dc.identifier.volume | 25 | |
dc.contributor.firstauthorID | 3371440 | |