Basit öğe kaydını göster

dc.contributor.authorKiziltas-Sendur, G.
dc.contributor.authorYılmaz, Ayça
dc.contributor.authorAslan, O. S.
dc.contributor.authorAbbott, P. V.
dc.contributor.authorHelvacioglu-Yigit, D.
dc.date.accessioned2021-03-03T07:36:15Z
dc.date.available2021-03-03T07:36:15Z
dc.date.issued2014
dc.identifier.citationHelvacioglu-Yigit D., Yılmaz A., Kiziltas-Sendur G., Aslan O. S. , Abbott P. V. , "Efficacy of Reciprocating and Rotary Systems for Removing Root Filling Material: A Micro-Computed Tomography Study", SCANNING, cilt.36, sa.6, ss.576-581, 2014
dc.identifier.issn0161-0457
dc.identifier.otherav_12da8265-deb0-4407-b0c6-4c5d9abdc41d
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/18119
dc.identifier.urihttps://doi.org/10.1002/sca.21157
dc.description.abstractThis study aimed to use micro-computed tomography (micro-CT) imaging to evaluate the efficacy of the reciprocating and rotary systems for the removal of root filling materials in comparison with hand files. Thirty maxillary incisor teeth were prepared with ProTaper Universal (PTU) system, filled using cold lateral condensation and randomly divided into three groups of ten teeth each. The root fillings were removed with WaveOne Reciprocating and ProTaper Universal Re-treatment (PTU-R) systems and hand files. Micro-CT was used to scan the specimens before and after each treatment step. Percentage of volume of residual root filling was measured. The operating time was recorded. PTU-R instruments yielded better results for removing filling material, even though there was no statistically significant difference between PTU-R and WaveOne groups. Reciprocating and rotary systems showed similar performances in terms of efficacy and operating time for root filling removal. SCANNING 36:576-581, 2014. (c) 2014 Wiley Periodicals, Inc.
dc.language.isoeng
dc.subjectMühendislik ve Teknoloji
dc.subjectMikrobiyoloji
dc.subjectTemel Bilimler
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectYaşam Bilimleri
dc.subjectMİKROSKOPİ
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectALETLER & GÖSTERİM
dc.titleEfficacy of Reciprocating and Rotary Systems for Removing Root Filling Material: A Micro-Computed Tomography Study
dc.typeMakale
dc.relation.journalSCANNING
dc.contributor.departmentKocaeli Üniversitesi , ,
dc.identifier.volume36
dc.identifier.issue6
dc.identifier.startpage576
dc.identifier.endpage581
dc.contributor.firstauthorID77043


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster