Basit öğe kaydını göster

dc.contributor.authorBANDELLO, F
dc.contributor.authorBRANCATO, R
dc.contributor.authorRENI, G
dc.contributor.authorDURANTE, A
dc.contributor.authorCERUTTI, S
dc.contributor.authorMAGNI, R
dc.contributor.authorGIUNTI, S
dc.contributor.authorBIANCHI, A
dc.date.accessioned2022-02-18T10:53:24Z
dc.date.available2022-02-18T10:53:24Z
dc.date.issued1994
dc.identifier.citationMAGNI R., GIUNTI S., BIANCHI A., RENI G., BANDELLO F., DURANTE A., CERUTTI S., BRANCATO R., "SINGLE-SWEEP ANALYSIS USING AN AUTOREGRESSIVE WITH EXOGENOUS INPUT (ARX) MODEL", DOCUMENTA OPHTHALMOLOGICA, cilt.86, sa.1, ss.95-104, 1994
dc.identifier.issn0012-4486
dc.identifier.otherav_c4790cdc-d731-42a6-9e2b-0b5002a43e0b
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/180105
dc.identifier.urihttps://doi.org/10.1007/bf01224631
dc.description.abstractSingle-sweep visual evoked potential analysis would be useful in clinical electrophysiology practice because it would make possible the evaluation of transient phenomena, but recording single-sweep visual evoked potentials is difficult because of the low signal-noise ratio. To increase this ratio we used a filter based on an autoregressive with exogenous input model. We studied a group of 12 diabetic patients matched with a control group of 14 normal subjects. The model, in most cases, allowed us to extrapolate the P100 component from each single sweep of visual evoked potential. The visual evoked potential values obtained by means of averaging were not significantly different in the groups studied, but single-sweep analysis showed different distribution of the P100 component amplitude. The preliminary results of our study evidenced differences in the amplitude and latency distribution of normal and diabetic subjects, thus confirming the power of this new technique and its ability to obtain some information that is masked by the averaging method.
dc.language.isoeng
dc.subjectOptometry
dc.subjectHealth Sciences
dc.subjectCerrahi Tıp Bilimleri
dc.subjectOphthalmology
dc.subjectGöz Hastalıkları ve Cerrahisi
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectOFTALMOLOJİ
dc.titleSINGLE-SWEEP ANALYSIS USING AN AUTOREGRESSIVE WITH EXOGENOUS INPUT (ARX) MODEL
dc.typeMakale
dc.relation.journalDOCUMENTA OPHTHALMOLOGICA
dc.contributor.department, ,
dc.identifier.volume86
dc.identifier.issue1
dc.identifier.startpage95
dc.identifier.endpage104
dc.contributor.firstauthorID3370999


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster