dc.date.issued2014
dc.identifier.citationOdemis E., Saygi M., Guzeltas A., Tanidir I. C. , Ergul Y., Ozyilmaz I., BAKIR İ., "Transcatheter Closure of Perimembranous Ventricular Septal Defects using Nit-Occlud((R)) L VSD Coil: Early and Mid-Term Results", PEDIATRIC CARDIOLOGY, cilt.35, sa.5, ss.817-823, 2014
dc.identifier.issn0172-0643
dc.identifier.othervv_1032021
dc.identifier.otherav_9281e342-bcd0-4e30-9f34-e8ff3f7debfe
dc.identifier.urihttp://hdl.handle.net/20.500.12627/179046
dc.identifier.urihttps://doi.org/10.1007/s00246-013-0860-8
dc.description.abstractOur objective was to investigate the short- and mid-term results of transcatheter ventricular septal defect (VSD) closure with the Nit-Occlud(A (R)) L VSD coil. Retrospective data collection study. Data were collected from 20 patients who underwent transcatheter VSD closure with the Nit-Occlud(A (R)) L VSD coil device between October 2011 and June 2013. The mean age of the study subjects was 7.3 +/- A 4.0 years, and the mean weight was 25.7 +/- A 11.8 kg. The distance between the defect and the aortic valve, measured using angiography, was an average of 5.1 +/- A 2.0 mm, and the left ventricular opening averaged 8.2 +/- A 2.1 mm. The mean value of the Q (p)/Q (s) ratio was 1.7 +/- A 0.4. Intravascular hemolysis developed in the first few hours after the procedure in three patients. In one of these cases, despite medical treatment and the implantation of a detachable coil placed into the Nit-Occlud(A (R)) device transcatheterly, hemolysis persisted. This device was removed and the VSD was closed surgically. In the other two cases, although the residual shunt persisted on echocardiography, the hemolysis regressed spontaneously. There were no rhythm problems or other complications during the follow-up period of 12.3 +/- A 6.6 months. In the selected cases, for the transcatheter treatment of VSD, the Nit-Occlud(A (R)) L VSD coil device can be used. When compared with other VSD closure devices, there was no development of a permanent atrioventricular block, which is an important advantage. However, patients with a residual shunt should be monitored closely for the development of hemolysis during the first few hours.
dc.language.isoeng
dc.subjectHealth Sciences
dc.subjectCARDIAC ve CARDIOVASCULAR SİSTEMLER
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectPEDİATRİ
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectÇocuk Sağlığı ve Hastalıkları
dc.subjectKardiyoloji
dc.subjectPediatrics
dc.subjectCardiology and Cardiovascular Medicine
dc.subjectPediatrics, Perinatology and Child Health
dc.titleTranscatheter Closure of Perimembranous Ventricular Septal Defects using Nit-Occlud((R)) L VSD Coil: Early and Mid-Term Results
dc.typeMakale
dc.relation.journalPEDIATRIC CARDIOLOGY
dc.contributor.departmentMehmet Akif Ersoy Cardiovasc Res & Training Hosp , ,
dc.identifier.volume35
dc.identifier.issue5
dc.identifier.startpage817
dc.identifier.endpage823