dc.contributor.author | UĞURLU, ADEM | |
dc.contributor.author | Ergül, Elif | |
dc.contributor.author | ALTINKURT, Emre | |
dc.date.accessioned | 2022-02-18T09:48:40Z | |
dc.date.available | 2022-02-18T09:48:40Z | |
dc.date.issued | 2021 | |
dc.identifier.citation | UĞURLU A., ALTINKURT E., Ergül E., "Comparison of prediction accuracy of five different biometric formulas Comparação da acurácia preditiva de cinco fórmulas biométricas diferentes", Revista Brasileira de Oftalmologia, cilt.80, sa.5, ss.1-5, 2021 | |
dc.identifier.issn | 0034-7280 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_613fe97e-cac6-43ab-b051-14817ad51a52 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/178028 | |
dc.identifier.uri | https://doi.org/10.37039/1982.8551.20210034 | |
dc.identifier.uri | https://avesis.istanbul.edu.tr/api/publication/613fe97e-cac6-43ab-b051-14817ad51a52/file | |
dc.description.abstract | © 2021. Revista Brasileira de Oftalmologia. All rights reserved.Objective: To compare the performance of Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function formulas to calculate intraocular lens power in eyes with normal axial length, in terms of predicting target refraction by using partial coherence interferometry technology. Methods: Phacoemulsification and intraocular lens implantation were performed in 135 eyes of 135 patients with an axial length between 22 and 24.5 mm. Axial length, keratometry, and anterior chamber depth were measured by intraocular lens Master 500. Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function formulas were used for intraocular lens power calculations. The difference between the expected postoperative refraction and the mean absolute prediction error was calculated for each eye. Statistical significance was evaluated at the level of p0.05). Conclusion: The study showed the third-generation (Sanders-Retzlaff-Kraft/Theoretical and Hoffer Q), fourth-generation (Barrett Universal II) and new-generation (Kane and Hill-radial basis function) intraocular lens power calculation formulas had similar performances regarding calculation of intraocular lens power to predict target refraction after phacoemulsification in eyes with normal axial length. | |
dc.language.iso | eng | |
dc.subject | Surgery | |
dc.subject | Health Sciences | |
dc.subject | Ophthalmology | |
dc.subject | Cerrahi Tıp Bilimleri | |
dc.subject | Göz Hastalıkları ve Cerrahisi | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Tıp | |
dc.subject | OFTALMOLOJİ | |
dc.subject | CERRAHİ | |
dc.subject | Klinik Tıp | |
dc.subject | Klinik Tıp (MED) | |
dc.title | Comparison of prediction accuracy of five different biometric formulas Comparação da acurácia preditiva de cinco fórmulas biométricas diferentes | |
dc.type | Makale | |
dc.relation.journal | Revista Brasileira de Oftalmologia | |
dc.contributor.department | Erzincan Binali Yıldırım Üniversitesi , Tıp Fakültesi , Cerrahi Tıp Bilimleri Bölümü | |
dc.identifier.volume | 80 | |
dc.identifier.issue | 5 | |
dc.identifier.startpage | 1 | |
dc.identifier.endpage | 5 | |
dc.contributor.firstauthorID | 3045216 | |