Basit öğe kaydını göster

dc.contributor.authorBilgili, Fuat
dc.contributor.authorKabukcuoglu, Yavuz
dc.contributor.authorKilic, Ayhan
dc.contributor.authorParmaksizoglu, Atilla Sancar
dc.contributor.authorOzkaya, Ufuk
dc.date.accessioned2022-02-18T09:14:25Z
dc.date.available2022-02-18T09:14:25Z
dc.date.issued2009
dc.identifier.citationOzkaya U., Bilgili F., Kilic A., Parmaksizoglu A. S. , Kabukcuoglu Y., "Minimally invasive management of unstable proximal femoral extracapsular fractures using reverse LISS femoral locking plates", HIP INTERNATIONAL, cilt.19, sa.2, ss.141-147, 2009
dc.identifier.issn1120-7000
dc.identifier.othervv_1032021
dc.identifier.otherav_285fc803-afe2-41a9-8b75-d5df26b51db7
dc.identifier.urihttp://hdl.handle.net/20.500.12627/176814
dc.identifier.urihttps://doi.org/10.1177/112070000901900211
dc.description.abstractThe efficacy of the reverse Less Invasive Plating System in the management of unstable proximal femoral extracapsular fractures was retrospectively evaluated. Twenty-seven patients with complex proximal femoral fractures were identified. There were three open fractures. The mean age was 71 years (range; 65-79). The mean follow up was 24 months (range; 15-32). The main outcome measures were union, union time, requirement for secondary procedures, development of deep infection, pain, and functional impairment. Nonunion was observed in one patient. The average Harris hip score at the last assessment was 73 points (range 58-85). The outcome was adversely affected by concomitant medical problems, anatomical reduction and fixation of the plate. The use of this plate in the management of proximal femoral fractures of all types may be a safe and alternative method to other treatment options. (Hip International 2009; 19: 141-7)
dc.language.isoeng
dc.subjectPodiatry
dc.subjectHealth Sciences
dc.subjectCerrahi Tıp Bilimleri
dc.subjectOrthopedics and Sports Medicine
dc.subjectOrtopedi ve Travmatoloji
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectORTOPEDİ
dc.titleMinimally invasive management of unstable proximal femoral extracapsular fractures using reverse LISS femoral locking plates
dc.typeMakale
dc.relation.journalHIP INTERNATIONAL
dc.contributor.departmentTaksim Training & Res Hosp , ,
dc.identifier.volume19
dc.identifier.issue2
dc.identifier.startpage141
dc.identifier.endpage147
dc.contributor.firstauthorID3215083


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster