Show simple item record

dc.contributor.authorARMAN ÖZÇIRPICI, AYÇA
dc.contributor.authorYILMAZ, Alev
dc.contributor.authorCehreli, Secil
dc.date.accessioned2022-02-18T08:58:13Z
dc.date.available2022-02-18T08:58:13Z
dc.date.issued2013
dc.identifier.citationCehreli S., ARMAN ÖZÇIRPICI A., YILMAZ A., "Tilted orthodontic micro implants: a photoelastic stress analysis", EUROPEAN JOURNAL OF ORTHODONTICS, cilt.35, sa.5, ss.563-567, 2013
dc.identifier.issn0141-5387
dc.identifier.othervv_1032021
dc.identifier.otherav_0d5366b1-802a-4147-9be0-38f1f7ab727b
dc.identifier.urihttp://hdl.handle.net/20.500.12627/176237
dc.identifier.urihttps://doi.org/10.1093/ejo/cjr070
dc.description.abstractThe aim of this study was to examine peri-implant stresses around orthodontic micro implants upon torque-tightening and static load application by quasi-three-dimensional photoelastic stress analysis. Self-tapping orthodontic micro implants were progressively inserted into photoelastic models at 30, 45, 70, and 90 degrees and insertion torques were measured. Stress patterns (isochromatic fringe orders) were recorded by the quasi-three - dimensional photoelastic method using a circular polariscope after insertion and 250 g static force application. Torque-tightening of implants generated peri-implant stresses. Upon insertion, 90 degree placed implants displayed the lowest and homogeneous stress distribution followed by 30, 70, and 45 degree tilted implants. Static loading did not dramatically alter stress fields around the implants tested. The highest alteration in stress distribution was observed for the 90 degree placed implant, while 70 degree tilted implant had the lowest stresses among tilted implants. Torque-tightening of orthodontic micro implants creates a stress field that is not dramatically altered after application of static lateral moderate orthodontic loads, particularly at the cervical region of tilted implants.
dc.language.isoeng
dc.subjectDentistry (miscellaneous)
dc.subjectGeneral Dentistry
dc.subjectHealth Sciences
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectDiş Hekimliği
dc.subjectOrthodontics
dc.subjectOral Surgery
dc.subjectDental Assisting
dc.subjectDental Hygiene
dc.subjectPeriodontics
dc.titleTilted orthodontic micro implants: a photoelastic stress analysis
dc.typeMakale
dc.relation.journalEUROPEAN JOURNAL OF ORTHODONTICS
dc.contributor.departmentBaşkent Üniversitesi , ,
dc.identifier.volume35
dc.identifier.issue5
dc.identifier.startpage563
dc.identifier.endpage567
dc.contributor.firstauthorID3381389