dc.contributor.author | Erdogan, Ozge | |
dc.contributor.author | Bilgin, Tayfun | |
dc.contributor.author | Geckili, Onur | |
dc.contributor.author | Bilhan, Hakan | |
dc.date.accessioned | 2021-12-10T13:04:19Z | |
dc.date.available | 2021-12-10T13:04:19Z | |
dc.date.issued | 2021 | |
dc.identifier.citation | Bilhan H., Erdogan O., Geckili O., Bilgin T., "Comparison of Marginal Bone Levels Around Tissue-Level Implants with Platform-Matched and Bone-Level Implants with Platform-Switching Connections: 1Year Results of a Prospective Cohort Study with a Split-Mouth Design", INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, cilt.36, sa.5, ss.945-951, 2021 | |
dc.identifier.issn | 0882-2786 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_ec4b42b3-914d-444c-9226-48333de7c653 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/175346 | |
dc.identifier.uri | https://doi.org/10.11607/jomi.8891 | |
dc.description.abstract | Purpose: This clinical study was conducted to compare the influence of a platform-switched bone-level implant and a platform-matched tissue-level implant on marginal bone loss during the first year after loading. Materials and Methods: Edentulous subjects who applied for two-implant-retained mandibular overdentures and showing sufficient bone volume for implants with 4.3-mm diameter and 12-mm length were enrolled. For standardization reasons, all subjects received a platform-matched tissue-level implant and a platform-switched bone-level implant in the anterior mandible. Since implants from the same manufacturer were used, both implants had identical implant thread designs and surface properties. All subjects received two-implant-retained mandibular overdentures with opposing maxillary complete dentures, and the implants were loaded after 6 weeks. Marginal bone loss was monitored via panoramic radiographs obtained immediately after loading and at the 6-and 12-month recalls after implant loading, and periodontal parameters, such as pocket probing depths, Plaque Index scores, and bleeding on probing, were also measured and recorded. Results: Twenty-six patients received 26 bone-level and 26 tissue-level implants. No statistically significant differences were detected between the bone loss of the two groups for all the measurements (P > .05). Additionally, no significant difference was detected between the measured periodontal parameters of the two groups (P > .05). Conclusion: Within the limitations of this prospective clinical study with a follow-up time of 12 months, it can be concluded that the platform-switching bone-level design and the platform-matching tissue-level design show similar bone loss in the anterior edentulous mandible. Inf./ Oral Maxillofac Implants 2021;36:945-951. doi: 10.11607/jomi.8891 | |
dc.language.iso | eng | |
dc.subject | DİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP | |
dc.subject | Dental Hygiene | |
dc.subject | Periodontics | |
dc.subject | Dental Assisting | |
dc.subject | General Dentistry | |
dc.subject | Health Sciences | |
dc.subject | Oral Surgery | |
dc.subject | Orthodontics | |
dc.subject | Diş Hekimliği | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Tıp | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Klinik Tıp | |
dc.subject | Dentistry (miscellaneous) | |
dc.title | Comparison of Marginal Bone Levels Around Tissue-Level Implants with Platform-Matched and Bone-Level Implants with Platform-Switching Connections: 1Year Results of a Prospective Cohort Study with a Split-Mouth Design | |
dc.type | Makale | |
dc.relation.journal | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS | |
dc.contributor.department | İstanbul Üniversitesi , Diş Hekimliği Fakültesi , Klinik Bilimleri | |
dc.identifier.volume | 36 | |
dc.identifier.issue | 5 | |
dc.identifier.startpage | 945 | |
dc.identifier.endpage | 951 | |
dc.contributor.firstauthorID | 2758993 | |