Basit öğe kaydını göster

dc.contributor.authorSaylan, Meltem
dc.contributor.authorBAKIRDERE, Sezgin
dc.contributor.authorZaman, Buse Tugba
dc.contributor.authorTopal, Serkan
dc.date.accessioned2021-12-10T12:26:00Z
dc.date.available2021-12-10T12:26:00Z
dc.identifier.citationTopal S., Saylan M., Zaman B. T. , BAKIRDERE S., "Determination of trace cadmium in saliva samples using spray assisted droplet formation-liquid phase microextraction prior to the measurement by slotted quartz tube-flame atomic absorption spectrophotometry", JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, cilt.68, 2021
dc.identifier.issn0946-672X
dc.identifier.othervv_1032021
dc.identifier.otherav_bc0498c0-871d-4a9d-8bfc-7eb0be705d4f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/173862
dc.identifier.urihttps://doi.org/10.1016/j.jtemb.2021.126859
dc.description.abstractBackground: An effective, green and rapid analytical strategy namely the simultaneous spray assisted droplet formation-liquid phase microextraction (S-SADF-LPME) method was developed for the determination of trace quantity of cadmium in saliva samples by using the slotted quartz tube-flame atomic absorption spectrophotometry (SQT-FAAS). By the developed method, external dispersive solvent usage for droplet formation was reduced to obtain a more environmental-friendly method. Methods: Method consists of a simultaneous complexing and extraction step, which was based on spraying an extraction solvent containing a solid ligand into the aqueous sample solution, forming fine droplets without the use of dispersive solvent. The procedure was implemented using a customized, cost effective and portable spray apparatus to minimize the consumption of reagent, analysis time and operation steps. Thus, this methodology ensures better repeatability and accuracy while minimizing the relative errors caused by the experimental steps. Parameters including the buffer amount, extractant/ligand concentration, extraction solvent type, extraction/ ligand solution volume, spraying number and vortex period were systemically optimized to lower the detection limit. Results: Under the optimal extraction conditions, 96.9-folds enhancement in the detection power of the traditional FAAS was achieved. The limit of detection and limit of quantification values of presented method were calculated to be 0.65 and 2.17 ng mL-1, respectively. Accuracy and applicability of the optimized method was investigated by collecting saliva samples from smokers. Satisfactory percent recovery values wereachieved for cadmium with a low standard deviation in the acceptable range of 84.9-109.6 %. Conclusion: The developed dispersive solvent-free S-SADF-LPME technique presents a fast, simple, cost-effective and eco-friendly microextraction method based on the use of an easily accessible and functional spray apparatus.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectİç Hastalıkları
dc.subjectEndokrinoloji ve Metabolizma Hastalıkları
dc.subjectYaşam Bilimleri
dc.subjectMoleküler Biyoloji ve Genetik
dc.subjectSitogenetik
dc.subjectTemel Bilimler
dc.subjectBiochemistry, Genetics and Molecular Biology (miscellaneous)
dc.subjectEndocrinology
dc.subjectClinical Biochemistry
dc.subjectCancer Research
dc.subjectMolecular Biology
dc.subjectEndocrine and Autonomic Systems
dc.subjectDrug Discovery
dc.subjectAging
dc.subjectKlinik Tıp (MED)
dc.subjectBiochemistry
dc.subjectStructural Biology
dc.subjectEndocrinology, Diabetes and Metabolism
dc.subjectLife Sciences
dc.subjectHealth Sciences
dc.subjectGeneral Biochemistry, Genetics and Molecular Biology
dc.subjectTıp
dc.subjectKlinik Tıp
dc.subjectENDOKRİNOLOJİ VE METABOLİZMA
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectMoleküler Biyoloji ve Genetik
dc.subjectBİYOKİMYA VE MOLEKÜLER BİYOLOJİ
dc.titleDetermination of trace cadmium in saliva samples using spray assisted droplet formation-liquid phase microextraction prior to the measurement by slotted quartz tube-flame atomic absorption spectrophotometry
dc.typeMakale
dc.relation.journalJOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY
dc.contributor.departmentİstanbul Teknik Üniversitesi , ,
dc.identifier.volume68
dc.contributor.firstauthorID2750473


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster