dc.identifier.citationBalkan B., Saygı Emir N., Çetingök H., Demirayak B., Bayrak B., "The effect of robotic surgery on intraocular pressure and optic nerve sheath diameter: a prospective study", BRAZILIAN JOURNAL OF ANESTHESIOLOGY, cilt.1, ss.1-5, 2021
dc.identifier.issn0104-0014
dc.identifier.othervv_1032021
dc.identifier.otherav_2204b6f8-4b71-480e-8858-c9f35ec4b35a
dc.identifier.urihttp://hdl.handle.net/20.500.12627/168982
dc.identifier.urihttps://reader.elsevier.com/reader/sd/pii/S0104001421001032?token=25B4E93663B151AC2231BEE2274E517D5B24D91E50C5EBFFBF51ED72F2271B6E26F777A78B60B70BE7248C8A2F7B41DF&originRegion=eu-west-1&originCreation=20211022101208
dc.identifier.urihttps://doi.org/10.1016/j.bjane.2021.02.035
dc.description.abstractAbstractBackground and objectives: To investigate the effect of the steep Trendelenburg position (35◦to 45◦) and carbon dioxide (CO2) insufflation on optic nerve sheath diameter (ONSD), intraocularpressure (IOP), and hemodynamic parameters in patients undergoing robot-assisted laparo-scopic prostatectomy (RALP), and to evaluate possible correlations between these parameters.Methods: A total of 34 patients were included in this study. ONSD was measured using ultra-sonography and IOP was measured using a tonometer at four time points: T1 (5 minutes afterintubation in the supine position); T2 (30 minutes after CO2 insufflation); T3 (120 minutes insteep Trendelenburg position); and T4 (in the supine position, after abdominal exsufflation).Systolic and diastolic arterial pressure, heart rate, and end-tidal CO2 (etCO2) were also evalu-ated.Results: The mean IOP was 12.4 mmHg at T1, 20 mmHg at T2, 21.8 mmHg at T3, and 15.6 mmHgat T4. The mean ONSD was 4.87 mm at T1, 5.21 mm at T2, 5.30 mm at T3, and 5.08 at T4. Therewas a statistically significant increase and decrease in IOP and ONSD between measurements atT1 and T4, respectively. However, no significant correlation was found between IOP and ONSD.A significant positive correlation was found only between ONSD and diastolic arterial pressure.Mean arterial pressure, heart rate, and etCO2 were not correlated with IOP or ONSD.Conclusions: A significant increase in IOP and ONSD were evident during RALP; however, therewas no significant correlation between the two parameters.
dc.language.isoeng
dc.subjectSurgery
dc.subjectAnesthesiology and Pain Medicine
dc.subjectHealth Sciences
dc.subjectCerrahi Tıp Bilimleri
dc.subjectAnesteziyoloji
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectANESTEZİYOLOJİ
dc.subjectCERRAHİ
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.titleThe effect of robotic surgery on intraocular pressure and optic nerve sheath diameter: a prospective study
dc.typeMakale
dc.relation.journalBRAZILIAN JOURNAL OF ANESTHESIOLOGY
dc.contributor.departmentSağlık Bilimleri Üniversitesi , İstanbul Mehmet Akif Ersoy Göğüs Kalp Ve Damar Cerrahisi Sağlık Uygulama Ve Araştırma Merkezi , Cerrahi Tıp Bilimleri Bölümü
dc.identifier.volume1
dc.identifier.startpage1
dc.identifier.endpage5
dc.contributor.firstauthorID2751689


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster