dc.contributor.authorHelvacioglu-Yigit, Dilek
dc.contributor.authorYilmaz, Ayça
dc.contributor.authorAydemir, Seda
dc.date.accessioned2021-03-06T21:16:18Z
dc.date.available2021-03-06T21:16:18Z
dc.date.issued2015
dc.identifier.citationHelvacioglu-Yigit D., Aydemir S., Yilmaz A., "Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study", BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, cilt.29, ss.368-373, 2015
dc.identifier.issn1310-2818
dc.identifier.otherav_fdfcf70f-a12c-4664-b53f-a340ba39f341
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/166126
dc.identifier.urihttps://doi.org/10.1080/13102818.2014.996982
dc.description.abstractThe purpose of this study was to evaluate the presence of dentinal defects after root canal preparation with hand instruments and two different reciprocating instruments. Sixty freshly extracted mandibular incisor teeth were selected for this in vitro study. On the basis of root length, mesiodistal and buccolingual dimensions, the teeth were allocated into three identical experimental groups (n = 15) and one control group (n = 15). The teeth in the control group were left unprepared. The other groups were: stainless steel hand instruments, WaveOne (R) Primary instruments and RECIPROC (R) R25 instruments. The reciprocating instruments were used with a reciprocating gentle in-and-out motion in a torque-limited electric motor at the appropriate preset mode. Horizontal sections were made 3, 6 and 9 mm from the apex. Samples were stained with methylene blue and viewed through a stereomicroscope. The presence of dentinal defects (fractures, incomplete cracks and craze lines) and their locations were investigated by two endodontists. These data were analysed statistically by Fisher's exact and chi-square tests. No defects were observed in the unprepared group. All instruments caused dentinal defects, with no significant differences between the instrument systems. All experimental groups demonstrated significantly more defects at the 3-mm level in comparison with the unprepared group (p = 0.032). At the other levels, there was no significant difference between the experimental groups and the control group. The use of hand or reciprocating instruments could induce the formation of dentinal defects during root canal preparation.
dc.language.isoeng
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectBiyoteknoloji
dc.subjectBİYOTEKNOLOJİ VE UYGULAMALI MİKROBİYOLOJİ
dc.subjectMikrobiyoloji
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.titleEvaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study
dc.typeMakale
dc.relation.journalBIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT
dc.contributor.departmentKocaeli Üniversitesi , ,
dc.identifier.volume29
dc.identifier.issue2
dc.identifier.startpage368
dc.identifier.endpage373