Show simple item record

dc.contributor.authorARHUN, NESLİHAN
dc.contributor.authorFiratli, Erhan
dc.contributor.authorOzel, Emre
dc.contributor.authorATTAR, NURAY
dc.contributor.authorFiratli, Sonmez
dc.contributor.authorGokcelik, Aylin
dc.contributor.authorÖZEL, YONCA
dc.date.accessioned2021-03-06T20:29:57Z
dc.date.available2021-03-06T20:29:57Z
dc.date.issued2007
dc.identifier.citationGokcelik A., ÖZEL Y., Ozel E., ARHUN N., ATTAR N., Firatli S., Firatli E., "The influence of Er : YAG laser conditioning versus self-etching adhesives with acid etching on the shear bond strength of orthodontic brackets", PHOTOMEDICINE AND LASER SURGERY, cilt.25, ss.508-512, 2007
dc.identifier.issn1549-5418
dc.identifier.otherav_fa72519c-8eae-416b-a202-3f52d156e58c
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/163986
dc.identifier.urihttps://doi.org/10.1089/pho.2007.2096
dc.description.abstractObjective: The aim of this study was to compare the shear bond strength (SBS) of orthodontic brackets after acid etching, laser ablation, self-etching primer application, and combined treatments. Methods: One hundred defect-free premolars were randomly assigned to five groups. The teeth received the following treatments: group 1: phosphoric acid + Transbond XT primer; group 2: Transbond Plus Self-Etching Primer (TPSEP); group 3: Er:YAG laser ablation + Transbond XT primer; group 4: Er:YAG laser ablation + phosphoric acid + Transbond XT primer; and group 5: Er:YAG laser ablation + TPSEP. Transbond XT Adhesive Paste was used in all groups for bracket bonding. Samples were stored in deionized water at 37 degrees C for 24 h. The shear debonding test was performed at a crosshead speed of 5 mm/min. Failed brackets were examined by a stereomicroscope at 16 X magnification to determine the bond failure interface using a modified adhesive remnant index (ARI). SBS values were compared using one-way analysis of variance (ANOVA). The Kruskal-Wallis test was used for ARI scores and pairwise comparisons were done using the Mann-Whitney U test with Bonferroni correction. Results: Mean SBS values (MPa) and standard deviations for the groups were: group 1, 13.18 +/- 3.45; group 2, 13.52 +/- 4.38; group 3, 10.33 +/- 4.74; group 41, 13.00 +/- 3.47; and group 5, 12.46 +/- 6.31. No significant differences were observed in the SBS of all the groups evaluated, but there was a significant difference in ARI scores, with group 3 showing higher ARI scores than groups 1 and 4. Conclusions: Er:YAG laser ablation and self-etching primer application showed similar SBS values as conventional acid-etching for bonding brackets.
dc.language.isoeng
dc.subjectKlinik Tıp
dc.subjectCerrahi Tıp Bilimleri
dc.subjectCERRAHİ
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.titleThe influence of Er : YAG laser conditioning versus self-etching adhesives with acid etching on the shear bond strength of orthodontic brackets
dc.typeMakale
dc.relation.journalPHOTOMEDICINE AND LASER SURGERY
dc.contributor.departmentBaşkent Üniversitesi , ,
dc.identifier.volume25
dc.identifier.issue6
dc.identifier.startpage508
dc.identifier.endpage512
dc.contributor.firstauthorID185493


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record