dc.identifier.citationAkbas U., Kesen N. D. , Koksal C., Okutan M., Demir B., Becerir H. B. , "Surface dose measurement with Gafchromic EBT3 film for intensity modulated radiotherapy technique", 3rd International Conference on Theoretical and Experimental Studies in Nuclear Applications and Technology (TESNAT), Adana, Türkiye, 10 - 12 Mayıs 2017, cilt.154
dc.identifier.othervv_1032021
dc.identifier.otherav_f38e6ef1-2ed9-4766-93eb-59d813474025
dc.identifier.urihttp://hdl.handle.net/20.500.12627/159716
dc.identifier.urihttps://doi.org/10.1051/epjconf/201715401011
dc.description.abstractAccurate dose measurement in the buildup region is extremely difficult. Studies have reported that treatment planning systems (TPS) cannot calculate surface dose accurately. The aim of the study was to compare the film measurements and TPS calculations for surface dose in head and neck cancer treatment using intensity modulated radiation therapy (IMRT). IMRT plans were generated for 5 head and neck cancer patients by using Varian Eclipse TPS. Quality assurance (QA) plans of these IMRT plans were created on rando phantoms for surface dose measurements. EBT3 films were cut in size of 2.5 x 2.5 cm(2) and placed on the left side, right side and the center of larynx and then the films were irradiated with 6 MV photon beams. The measured doses were compared with TPS. The results of TPS calculations were found to be lower compared to the EBT3 film measurements at all selected points. The lack of surface dose calculation in TPS should be considered while evaluating the radiotherapy plans.
dc.language.isoeng
dc.subjectNükleer Fizik
dc.subjectTemel Bilimler
dc.subjectFİZİK, NÜKLEER
dc.subjectTemel Bilimler (SCI)
dc.subjectFizik
dc.subjectNÜKLEAR BİLİMİ VE TEKNOLOJİSİ
dc.titleSurface dose measurement with Gafchromic EBT3 film for intensity modulated radiotherapy technique