Basit öğe kaydını göster

dc.contributor.authorDago, Angela
dc.contributor.authorAydogmus, Zeynep
dc.contributor.authorKauffmann, Jean-Michel
dc.contributor.authorDewert, Jean-Yves
dc.contributor.authorSarakbi, Ahmad
dc.contributor.authorMertens, Dominique
dc.date.accessioned2021-03-06T12:19:38Z
dc.date.available2021-03-06T12:19:38Z
dc.identifier.citationSarakbi A., Aydogmus Z., Dago A., Mertens D., Dewert J., Kauffmann J., "Determination of aminothiols by liquid chromatography with amperometric detection at a silver electrode: Application to white wines", ANALYTICA CHIMICA ACTA, cilt.786, ss.22-28, 2013
dc.identifier.issn0003-2670
dc.identifier.otherav_f344fcf6-b23a-4fdb-9705-8e78b008d304
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/159543
dc.identifier.urihttps://doi.org/10.1016/j.aca.2013.04.070
dc.description.abstractLiquid chromatography coupled to a silver electrode based flow-through amperometric detector (LC-EC-Ag) was developed for the determination of aminothiols in white wines. The C18 reversed phase LC system operated in the isocratic mode at 0.7mLmin−1 and used an acidic mobile phase composed of formic acid, EDTA, sodium nitrate, sodium hydroxide, and methanol 1% (v/v) at pH 4.5. The working electrode operated at 0.08V vs Ag/AgCl, 3M KCl and its manual cleaning was realized once a month by smoothing on a polishing cloth. The analyzed aminothiols were resolved and eluted within 4min, and all standard curves were linear in the range 2×10-7–2×10-5M. The analyzed wine samples needed no preparation other than dilution with the mobile phase. The concentration of cysteine (CYS), homocysteine (HCYS), glutathione (GSH) and N-acetylcysteine (NAC) in bottled white wines, determined by the method of standard addition, was found to be in the low μM range (0.2–2mgL−1) depending on the wine type and its age
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectKimya
dc.subjectTemel Bilimler (SCI)
dc.subjectKİMYA, ANALİTİK
dc.subjectAnalitik Kimya
dc.titleDetermination of aminothiols by liquid chromatography with amperometric detection at a silver electrode: Application to white wines
dc.typeMakale
dc.relation.journalANALYTICA CHIMICA ACTA
dc.contributor.departmentUniversite Libre De Bruxelles , ,
dc.identifier.volume786
dc.identifier.startpage22
dc.identifier.endpage28
dc.contributor.firstauthorID459103


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster