Show simple item record

dc.contributor.authorGrozev, Nikolay A.
dc.contributor.authorÇelik, Mehmet Sabri
dc.contributor.authorÖZDEMİR, Orhan
dc.contributor.authorKarakashev, Stoyan
dc.contributor.authorBoylu, Feridun
dc.contributor.authorGuven, Onur
dc.contributor.authorBatjargal, Khandjamts
dc.date.accessioned2021-03-06T11:45:51Z
dc.date.available2021-03-06T11:45:51Z
dc.date.issued2020
dc.identifier.citationGuven O., Batjargal K., ÖZDEMİR O., Karakashev S., Grozev N. A. , Boylu F., Çelik M. S. , "Experimental Procedure for the Determination of the Critical Coalescence Concentration (CCC) of Simple Frothers", MINERALS, cilt.10, 2020
dc.identifier.issn2075-163X
dc.identifier.otherav_f099e16c-a6b7-4047-9a30-7e6bbfdc6065
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/157883
dc.identifier.urihttps://doi.org/10.3390/min10070617
dc.description.abstractIn this study, the critical coalescence concentrations (CCC) of selected commercial frother solutions, namely polypropylene glycols (PPG 200, 400, and 600), tri propylene glycol (BTPG), triethylene glycol (BTEG), dipropylene glycol (BDPG), and as a reference, methyl isobutyl carbinol (MIBC), were determined using a bubble column based on light absorption. The results for all seven frothers showed that BTEG has the worst bubble inhibiting performance, and PPG 600 has the best bubble inhibiting performance. While critical coalescence concentration (CCC) was found as 3 ppm for PPG 600, it increased to 25 ppm for BTEG. In the case of MIBC, which was the reference point, the CCC value was found as 10 ppm, which was consistent with the literature. The surface tension isotherms of the frothers were determined and analyzed with one of the latest adsorption models. The results indicated that the polypropylene glycol frothers showed more surface activity compared to alcohol or other frothers investigated. This is due to the additional reorganization of the PPG molecules on the air/water interface, thus boosting its surface activity.
dc.language.isoeng
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik ve Teknoloji
dc.subjectMaden Mühendisliği ve Teknolojisi
dc.subjectMühendislik
dc.subjectMADEN VE MİNERAL İŞLEM
dc.subjectTemel Bilimler (SCI)
dc.subjectYerbilimleri
dc.subjectMİNERALOJİ
dc.titleExperimental Procedure for the Determination of the Critical Coalescence Concentration (CCC) of Simple Frothers
dc.typeMakale
dc.relation.journalMINERALS
dc.contributor.departmentAdana Alparslan Turkes Science & Technology University , ,
dc.identifier.volume10
dc.identifier.issue7
dc.contributor.firstauthorID2284312


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record