Basit öğe kaydını göster

dc.contributor.authorKorkmaz, Yonca
dc.contributor.authorBicer, Ceren Ozge
dc.contributor.authorATTAR, NURAY
dc.contributor.authorOzel, Emre
dc.contributor.authorFiratli, Erhan
dc.date.accessioned2021-03-06T11:40:31Z
dc.date.available2021-03-06T11:40:31Z
dc.date.issued2009
dc.identifier.citationOzel E., Korkmaz Y., ATTAR N., Bicer C. O. , Firatli E., "Leakage Pathway of Different Nano-Restorative Materials in Class V Cavities Prepared by Er:YAG Laser and Bur Preparation", PHOTOMEDICINE AND LASER SURGERY, cilt.27, ss.783-789, 2009
dc.identifier.issn1549-5418
dc.identifier.othervv_1032021
dc.identifier.otherav_f01f6bf3-438b-44aa-80a2-3736657d2e7c
dc.identifier.urihttp://hdl.handle.net/20.500.12627/157601
dc.identifier.urihttps://doi.org/10.1089/pho.2008.2313
dc.description.abstractObjective: The aim of this study was to evaluate the microleakage of different nano-restorative materials in Class V cavities prepared by Er:YAG laser and bur preparation. Materials and Methods: Class V cavities were prepared on the buccal and lingual surfaces of 72 premolars by Er:YAG laser or bur. The occlusal margins were in enamel and the cervical margins were in cementum. Teeth were randomly assigned to six groups of 12 teeth (n = 24 cavities) each as follows: Group 1, Er:YAG laser preparation (E)+Ketac N100 (K); Group 2, bur preparation (B)+K; Group 3, E+Adper Prompt L-Pop (A)+Filtek Supreme XT Flow (FSF); Group 4, B+A+FSF; Group 5, E+A+Filtek Supreme XT (FS); Group 6, B+A+FS. All teeth were thermocycled 500 times. Ten teeth from each group were chosen for the microleakage investigation and two teeth for the scanning electron microscope evaluation. Teeth prepared for the microleakage test were immersed in 0.5% basic fuchsin dye for 24 h. Afterwards, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests (p 0.05). Conclusion: It may be concluded that the cavities prepared by Er:YAG laser showed higher degree of microleakage than those conventionally prepared by bur, regardless of the restorative material at enamel margins.
dc.language.isoeng
dc.subjectCerrahi Tıp Bilimleri
dc.subjectCERRAHİ
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.titleLeakage Pathway of Different Nano-Restorative Materials in Class V Cavities Prepared by Er:YAG Laser and Bur Preparation
dc.typeMakale
dc.relation.journalPHOTOMEDICINE AND LASER SURGERY
dc.contributor.departmentKocaeli Üniversitesi , ,
dc.identifier.volume27
dc.identifier.issue5
dc.identifier.startpage783
dc.identifier.endpage789
dc.contributor.firstauthorID193745


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster