Basit öğe kaydını göster

dc.contributor.authorDogutan, M
dc.contributor.authorFilik, H
dc.contributor.authorTor, I
dc.date.accessioned2021-03-06T11:38:25Z
dc.date.available2021-03-06T11:38:25Z
dc.date.issued2003
dc.identifier.citationDogutan M., Filik H., Tor I., "Preconcentration and speciation of chromium using a melamine based polymeric sequestering succinic acid resin: its application for Cr(VI) and Cr(III) determination in wastewater", TALANTA, cilt.59, ss.1053-1060, 2003
dc.identifier.issn0039-9140
dc.identifier.otherav_efffc620-2c1e-4906-9f38-ba56c8deade3
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/157515
dc.identifier.urihttps://doi.org/10.1016/s0039-9140(03)00002-x
dc.description.abstractA new melamine based polymeric sequestering resin was prepared for preconcentration and separation of hexavalent chromium from water, and its sequestering action was investigated. The water-insoluble, cross-linked sequestering resin was formed by reaction with bromosuccinic acid and cross-linking of melamine. The active sequestering group on the resin is -NH-(Succinic acid) or salt thereof. The resulting chelating resin was characterized by infrared spectra. The newly prepared resin quantitatively retained Cr(VI) at pH 2.0-4.0 when the flow rate was maintained between 1 and 5 ml min(-1). The retained Cr(VI) was instantaneously eluted with 25 ml of 0.1 M NaOH. The chromium species were determined by a flame atomic absorption spectrometer. The limits of detection for Cr(VI) and Cr(III) were found to be 5.3 and 4.2 mug 1(-1), respectively. The precision and accuracy of the proposed procedure was checked by the use synthetic and reference steel samples. The established preconcentration method was successfully applied to the determination and selective separation of Cr(VI) in electroplating industry wastewater. Total concentrations determined by the spectrophotometric method (110.3+/-0.6 g 1(-1) Cr(VI) and 1.2+/-0.3 g 1(-1) Cr(III)) are compared with those found by FAAS and the obtained results (110.4+/-1.8 g 1(-1) Cr(VI) and 1.4+/-0.5 g 1(-1) Cr(III)) show good agreement. (C) 2003 Published by Elsevier Science B.V.
dc.language.isoeng
dc.subjectTemel Bilimler (SCI)
dc.subjectTemel Bilimler
dc.subjectKİMYA, ANALİTİK
dc.subjectKimya
dc.subjectAnalitik Kimya
dc.titlePreconcentration and speciation of chromium using a melamine based polymeric sequestering succinic acid resin: its application for Cr(VI) and Cr(III) determination in wastewater
dc.typeMakale
dc.relation.journalTALANTA
dc.contributor.department, ,
dc.identifier.volume59
dc.identifier.issue5
dc.identifier.startpage1053
dc.identifier.endpage1060
dc.contributor.firstauthorID15535


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster