Basit öğe kaydını göster

dc.contributor.authorKoksal, Canan
dc.contributor.authorAkbas, Ugur
dc.contributor.authorBilge, Hatice
dc.contributor.authorKesen, Nazmiye Donmez
dc.date.accessioned2021-03-06T11:17:51Z
dc.date.available2021-03-06T11:17:51Z
dc.date.issued2019
dc.identifier.citationKesen N. D. , Akbas U., Koksal C., Bilge H., "Investigation of AAA dose calculation algorithm accuracy in surface and buildup region for 6MV photon beam using markus parallel-plate ion chamber", Journal of X-Ray Science and Technology, cilt.27, ss.361-369, 2019
dc.identifier.issn0895-3996
dc.identifier.othervv_1032021
dc.identifier.otherav_ee5834ae-0d05-46db-af02-39de8e6fcdf4
dc.identifier.urihttp://hdl.handle.net/20.500.12627/156468
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85065207268&origin=inward
dc.identifier.urihttps://doi.org/10.3233/xst-180489
dc.description.abstractIn radiotherapy, dose distributions are obtained by using dose calculation algorithms that are implanted in treatment planning systems (TPS). This study aims to compare the surface doses of separate field sizes calculated by different version of The Analytical Anisotropic Algorithm (AAA) and measured by the parallel-plate ion chamber that is admitted as the most reliable dosimetry system for the surface region dose measurements. In order to measure the near surface dose, water equivalent solid phantom was used and measurements were made for 6MV photon beam at 100 cm source-detector distance for 5x5, 10x10, and 20x20 cm(2) field sizes. AAA 8.9 and AAA 15.1 versions of the Varian Eclipse TPS were used for surface dose calculations by generating beams with separate field sizes. The doses were read by considering the effective buildup thickness of Markus parallel-plate ion chamber. The surface doses using 6MV photon beams for 10x10 cm2 field size at 0.07 mm were found to be 11.04%, 26.25%, and 19.69% for AAA v8.9, AAA v15.1 and Markus chamber, respectively. It was seen that for both of the AAA versions and Markus parallel-plate ion chamber, increasing field sizes also increase surface dose. For all field sizes, surface dose was lowest by using AAA v8.9 at 0.07 mm. The different versions of the same TPS algorithms may calculate the surface doses distinctively. After upgrading of TPS algorithms, surface doses should be calculated and compared by measurements with different dosimetry systems to better understand their calculation behaviors in the near surface region.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectElektromanyetizma, Akustik, Isı Transferi, Klasik Mekanik ve Akışkanlar Dinamiği
dc.subjectOptik
dc.subjectFİZİK, UYGULAMALI
dc.subjectTemel Bilimler (SCI)
dc.subjectFizik
dc.subjectOPTİK
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectALETLER & GÖSTERİM
dc.titleInvestigation of AAA dose calculation algorithm accuracy in surface and buildup region for 6MV photon beam using markus parallel-plate ion chamber
dc.typeMakale
dc.relation.journalJournal of X-Ray Science and Technology
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume27
dc.identifier.issue2
dc.identifier.startpage361
dc.identifier.endpage369
dc.contributor.firstauthorID259859