Basit öğe kaydını göster

dc.contributor.authorKESKINLER, B
dc.contributor.authorKOCAKERIM, MM
dc.contributor.authorYILMAZ, AE
dc.contributor.authorBoncukcuoglu, Recep
dc.date.accessioned2021-03-06T11:11:56Z
dc.date.available2021-03-06T11:11:56Z
dc.identifier.citationYILMAZ A., Boncukcuoglu R., KOCAKERIM M., KESKINLER B., "The investigation of parameters affecting boron removal by electrocoagulation method", JOURNAL OF HAZARDOUS MATERIALS, cilt.125, ss.160-165, 2005
dc.identifier.issn0304-3894
dc.identifier.othervv_1032021
dc.identifier.otherav_ede2cbea-fe6d-4c13-82d8-4cfc44ef3d64
dc.identifier.urihttp://hdl.handle.net/20.500.12627/156181
dc.identifier.urihttps://doi.org/10.1016/j.jhazmat.2005.05.020
dc.description.abstractBoron removal from wastewaters by electrocoagulation using aluminum electrode material was investigated in this paper. Several working parameters, such as pH, current density, boron concentration and type and concentration of supporting electrolyte were studied in an attempt to achieve a higher removal capacity. The experiments were carried out by keeping the pH of solution constant and optimum pH of solution was determined 8.0 for the aluminum electrode. Although energy consumption increased with decreasing boron concentration, which conductivity of these solutions were low, boron removal efficiency was higher at 100 mg/L than that of 1000 mg/L. Current density was an important parameter affecting removal efficiency. Boron removal efficiency and energy consumption increased with increasing current density from 1.2 to 6.0 mA/cm(2). The types of different supporting electrolyte were experimented in order to investigate to this parameter effect on boron removal. The highest boron removal efficiency, 97%, was found by CaCl2 Added CaCl2 increased more the conductivity of solution according to other supporting electrolytes, but decreased energy consumption. The results showed to have a high effectiveness of the electrocoagulation method in removing boron from aqueous solutions. (c) 2005 Elsevier B.V. All rights reserved.
dc.language.isoeng
dc.subjectTarımsal Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectÇevre Mühendisliği
dc.subjectMÜHENDİSLİK, ÇEVRE
dc.subjectMühendislik
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectÇEVRE BİLİMLERİ
dc.subjectÇevre / Ekoloji
dc.titleThe investigation of parameters affecting boron removal by electrocoagulation method
dc.typeMakale
dc.relation.journalJOURNAL OF HAZARDOUS MATERIALS
dc.contributor.departmentAtatürk Üniversitesi , ,
dc.identifier.volume125
dc.identifier.startpage160
dc.identifier.endpage165
dc.contributor.firstauthorID103190


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster