dc.contributor.author | Karakoyun, Sueleyman | |
dc.contributor.author | Oezkan, Mehmet | |
dc.contributor.author | Guersoy, Ozan Mustafa | |
dc.contributor.author | ASTARCIOĞLU, MEHMET ALİ | |
dc.contributor.author | Guenduez, Sabahattin | |
dc.contributor.author | Cakal, Beytullah | |
dc.contributor.author | Cevik, Cihan | |
dc.contributor.author | Yildiz, Mustafa | |
dc.contributor.author | Duran, Niluefer Eksi | |
dc.contributor.author | Kahveci, Goekhan | |
dc.contributor.author | Kalcik, Macit | |
dc.date.accessioned | 2021-03-06T11:05:10Z | |
dc.date.available | 2021-03-06T11:05:10Z | |
dc.date.issued | 2013 | |
dc.identifier.citation | Oezkan M., Guersoy O. M. , ASTARCIOĞLU M. A. , Guenduez S., Cakal B., Karakoyun S., Kalcik M., Kahveci G., Duran N. E. , Yildiz M., et al., "Real-Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Mechanical Prosthetic Mitral Valve Ring Thrombosis", AMERICAN JOURNAL OF CARDIOLOGY, cilt.112, ss.977-983, 2013 | |
dc.identifier.issn | 0002-9149 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_ed6bd6c1-e70d-43ee-8f49-d7d4e1bbd93e | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/155867 | |
dc.identifier.uri | https://doi.org/10.1016/j.amjcard.2013.05.032 | |
dc.description.abstract | Although 2-dimensional (2D) transesophageal echocardiography (TEE) is the gold standard for the diagnosis of prosthetic valve thrombosis, nonobstructive clots located on mitral valve rings can be missed. Real-time 3-dimensional (3D) TEE has incremental value in the visualization of mitral prosthesis. The aim of this study was to investigate the utility of real-time 3D TEE in the diagnosis of mitral prosthetic ring thrombosis. The clinical outcomes of these patients in relation to real-time 3D transesophageal echocardiographic findings were analyzed. Of 1,263 patients who underwent echocardiographic studies, 174 patients (37 men, 137 women) with mitral ring thrombosis detected by real-time 3D TEE constituted the main study population. Patients were followed prospectively on oral anticoagulation for 25 +/- 7 months. Eighty-nine patients (51%) had thrombi that were missed on 2D TEE and depicted only on real-time 3D TEE. The remaining cases were partially visualized with 2D TEE but completely visualized with real-time 3D TEE. Thirty-seven patients (21%) had thromboembolism. The mean thickness of the ring thrombosis in patients with thromboembolism was greater than that in patients without thromboembolism (3.8 +/- 0.9 vs 2.8 +/- 0.7 mm, p <0.001). One hundred fifty-five patients (89%) underwent real-time 3D TEE during follow-up. There were no thrombi in 39 patients (25%); 45 (29%) had regression of thrombi, and there was no change in thrombus size in 68 patients (44%). Thrombus size increased in 3 patients (2%). Thrombosis was confirmed surgically and histopathologically in 12 patients (7%). In conclusion, real-time 3D TEE can detect prosthetic mitral ring thrombosis that could be missed on 2D TEE and cause thromboembolic events. (c) 2013 Elsevier Inc. All rights reserved. | |
dc.language.iso | eng | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Tıp | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Dahili Tıp Bilimleri | |
dc.subject | Kardiyoloji | |
dc.subject | Cardiology and Cardiovascular Medicine | |
dc.subject | Health Sciences | |
dc.subject | Klinik Tıp | |
dc.subject | CARDIAC ve CARDIOVASCULAR SİSTEMLER | |
dc.title | Real-Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Mechanical Prosthetic Mitral Valve Ring Thrombosis | |
dc.type | Makale | |
dc.relation.journal | AMERICAN JOURNAL OF CARDIOLOGY | |
dc.contributor.department | Istanbul Kartal Kosuyolu Yuksek Ihtisas Training & Research Hospital , , | |
dc.identifier.volume | 112 | |
dc.identifier.issue | 7 | |
dc.identifier.startpage | 977 | |
dc.identifier.endpage | 983 | |
dc.contributor.firstauthorID | 2507719 | |