Basit öğe kaydını göster

dc.contributor.authorOzdemir, Tayfun
dc.contributor.authorArisan, Volkan
dc.contributor.authorKarabuda, Zihni Cuneyt
dc.contributor.authorAvsever, Hakan
dc.date.accessioned2021-03-06T11:02:34Z
dc.date.available2021-03-06T11:02:34Z
dc.date.issued2013
dc.identifier.citationArisan V., Karabuda Z. C. , Avsever H., Ozdemir T., "Conventional Multi-Slice Computed Tomography (CT) and Cone-Beam CT (CBCT) for Computer-Assisted Implant Placement. Part I: Relationship of Radiographic Gray Density and Implant Stability", CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, cilt.15, ss.893-906, 2013
dc.identifier.issn1523-0899
dc.identifier.otherav_ed367049-77e2-4a5f-9bc0-3b9edb631100
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/155721
dc.identifier.urihttps://doi.org/10.1111/j.1708-8208.2011.00436.x
dc.description.abstractPurpose: The relationship of conventional multi-slice computed tomography (CT)- and cone beam CT (CBCT)-based gray density values and the primary stability parameters of implants that were placed by stereolithographic surgical guides were analyzed in this study. Materials and Methods: Eighteen edentulous jaws were randomly scanned by a CT (CT group) or a CBCT scanner (CBCT group) and radiographic gray density was measured from the planned implants. A total of 108 implants were placed, and primary stability parameters were measured by insertion torque value (ITV) and resonance frequency analysis (RFA). Radiographic and subjective bone quality classification (BQC) was also classified. Results were analyzed by correlation tests and multiple regressions (p<.05). Results: CBCT-based gray density values (76597.32 voxel value) outside the implants were significantly higher than those of CT-based values (668.4 +/- 110 Hounsfield unit, p<.001). Significant relations were found among the gray density values outside the implants, ITV (adjusted r(2)=0.6142, p=.001 and adjusted r(2)=0.5166, p=.0021), and RFA (adjusted r(2)=0.5642, p=.0017 and adjusted r(2)=0.5423, p=.0031 for CT and CBCT groups, respectively). Data from radiographic and subjective BQC were also in agreement. Conclusions: Similar to the gray density values of CT, that of CBCT could also be predictive for the subjective BQC and primary implant stability. Results should be confirmed on different CBCT scanners.
dc.language.isoeng
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectKlinik Tıp
dc.subjectTıp
dc.subjectDiş Hekimliği
dc.titleConventional Multi-Slice Computed Tomography (CT) and Cone-Beam CT (CBCT) for Computer-Assisted Implant Placement. Part I: Relationship of Radiographic Gray Density and Implant Stability
dc.typeMakale
dc.relation.journalCLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH
dc.contributor.departmentGulhane Military Medical Academy , ,
dc.identifier.volume15
dc.identifier.issue6
dc.identifier.startpage893
dc.identifier.endpage906
dc.contributor.firstauthorID55515


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster