Show simple item record

dc.contributor.authorJean-Pierre, Helene
dc.contributor.authorToprak, Nurver Ulger
dc.contributor.authorAlida, Veloo C. M.
dc.contributor.authorUrban, Edit
dc.contributor.authorWybo, Ingrid
dc.contributor.authorJustesen, Ulrik S.
dc.contributor.authorKulekci, Guven
dc.contributor.authorMorris, Trefor
dc.contributor.authorAkgul, Oncu
dc.contributor.authorSoyletir, Guner
dc.contributor.authorNagy, Elisabeth
dc.contributor.authorTripkovic, Vesna
dc.contributor.authorLeitner, Eva
dc.contributor.authorJeverica, Samo
dc.contributor.authorStingue, Suzana C.
dc.contributor.authorRodloff, Arne C.
dc.contributor.authorPaparaskevas, Joseph
dc.contributor.authorJamal, Wafaa
dc.contributor.authorRotimi, Vincent O.
dc.contributor.authorTokman, Hrisi B.
dc.date.accessioned2021-03-06T10:09:04Z
dc.date.available2021-03-06T10:09:04Z
dc.identifier.citationToprak N. U. , Alida V. C. M. , Urban E., Wybo I., Justesen U. S. , Jean-Pierre H., Morris T., Akgul O., Kulekci G., Soyletir G., et al., "Performance of mass spectrometric identification of clinical Prevotella species using the VITEK MS system: A prospective multi-center study", ANAEROBE, cilt.54, ss.205-209, 2018
dc.identifier.issn1075-9964
dc.identifier.othervv_1032021
dc.identifier.otherav_e8f6a549-965c-4db3-96fd-a2c41c1939cb
dc.identifier.urihttp://hdl.handle.net/20.500.12627/153095
dc.identifier.urihttps://doi.org/10.1016/j.anaerobe.2018.05.016
dc.description.abstractPrevotella species, members of the human microbiota, can cause opportunistic infections. Rapid and accurate identification of Prevotella isolates plays a critical role in successful treatment, especially since the antibiotic susceptibility profile differs between species. Studies, mostly carried out using the Matrix Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) Biotyper system, showed that MALDI-TOF MS is an accurate, rapid and satisfactory method for the identification of clinically important anaerobes. In this multi-center study, we assessed the performance of the MALDI-TOF MS VITEK MS system for the identification of clinical Prevotella isolates. A total of 508 Prevotella isolates, representing 19 different species, collected from 11 European countries, Kuwait and Turkey between January 2014 and April 2016, were identified using VITEK MS (v3.0). The reliability of the identification was assessed by 16S rRNA gene sequencing. Using VITEK MS, 422 (83.1%) of the 508 isolates were identified on the species level, 459 (90.4%) on the genus level. A total of 49 (9.6%) isolates were not identified correctly. 16S rRNA gene sequencing results showed that this was partly due to the fact that several species were not represented in the database. However, some species that were represented in the database were also not identified. Five Prevotella strains were misidentified at the genus level, 2 of these strains belonged to a species not represented in the database. In general, the VITEK MS offers a reliable and rapid identification of Prevotella species, however the databases needs to be expanded. (C) 2018 Published by Elsevier Ltd.
dc.language.isoeng
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectMikrobiyoloji
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.titlePerformance of mass spectrometric identification of clinical Prevotella species using the VITEK MS system: A prospective multi-center study
dc.typeMakale
dc.relation.journalANAEROBE
dc.contributor.departmentMarmara Üniversitesi , ,
dc.identifier.volume54
dc.identifier.startpage205
dc.identifier.endpage209
dc.contributor.firstauthorID259140


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record