| dc.identifier.citation | Topuz S., Alpertunga B., "Determination of triazines and N-methylcarbamate pesticides in water by high-performance liquid chromatography-diode array detection", INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, cilt.83, ss.787-795, 2003 | |
| dc.identifier.issn | 0306-7319 | |
| dc.identifier.other | av_e11f7e51-1a1e-4e38-9414-5b7a9df1ccf2 | |
| dc.identifier.other | vv_1032021 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.12627/148231 | |
| dc.identifier.uri | https://doi.org/10.1080/0306731031000104731 | |
| dc.description.abstract | A rapid and selective method for the simultaneous determination of triazine herbicides (atrazine, its degradation product desethylatrazine, simazine, prometryn, terbutryn) and N -methylcarbamate insecticides (propoxur, carbaryl and methiocarb) in surface water has been developed. A 0.5 L of the water sample was preconcentrated by passage through a 1 g C-18 solid-phase extraction cartridge. The retained compounds were eluted with 5 mL of methanol from the cartridge. The pesticides were separated and quantified by reversed-phase high-performance liquid chromatography with UV diode-array detection. Analytical separation was performed using a concave gradient elution with acetonitrile and water on a C-18 column. Prometryn and terbutryn were determined at 240 nm; propoxur, methiocarb at 204 nm and the others at 220 nm. Recoveries varied from 85 to 102% over concentrations at 0.025 and 0.2 mug L-1. The limits of detection for the compounds investigated are in the range of 0.005-0.012 mug L-1. | |
| dc.language.iso | eng | |
| dc.subject | Analitik Kimya | |
| dc.subject | Temel Bilimler | |
| dc.subject | Mühendislik ve Teknoloji | |
| dc.subject | Tarım ve Çevre Bilimleri (AGE) | |
| dc.subject | Çevre Mühendisliği | |
| dc.subject | Tarımsal Bilimler | |
| dc.subject | Çevre / Ekoloji | |
| dc.subject | ÇEVRE BİLİMLERİ | |
| dc.subject | Temel Bilimler (SCI) | |
| dc.subject | Kimya | |
| dc.subject | KİMYA, ANALİTİK | |
| dc.title | Determination of triazines and N-methylcarbamate pesticides in water by high-performance liquid chromatography-diode array detection | |
| dc.type | Makale | |
| dc.relation.journal | INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY | |
| dc.contributor.department | İstanbul Üniversitesi , Eczacılık Fakültesi , Eczacılık Meslek Bilimleri Bölümü | |
| dc.identifier.volume | 83 | |
| dc.identifier.issue | 9 | |
| dc.identifier.startpage | 787 | |
| dc.identifier.endpage | 795 | |
| dc.contributor.firstauthorID | 14647 | |