dc.description.abstractIntroduction: It is possible to detect venous gas bubbles by listening to the Doppler audio signals. However, a serious disadvantage of the audio evaluation is the inability of continuous monitoring and the inter-rater agreement. Several researchers have worked on the automated detection of emboli, but no current system has the required sensitivity and specificity for clinical use. Method: We developed software that integrated frequency filtering, processing, and detection phases of microemboli into a graphical user interface. The detection algorithm consists of a rule-based criterion with a user-defined threshold sliding in-time axis that estimates the duration of the embolic event. Subclavian Doppler audio recordings obtained from a high altitude diving expedition were analyzed using digital filtering and non-linear operator combinations of the software. The data set includes 43 embolic events in 9 recordings from 4 different subjects. Results: It was determined that embolic signals are best differentiated from the background signal at the 4500-8000-Hz frequency hand. By using the non-linear "Teager Energy Operator," embolic signals were amplified against their background and a high level of sensitivity and specificity was obtained (83.7% and 97.3%, respectively). The duration of the detected emboli was estimated as 12.17 +/- 4.36 ms (mean +/- SD). Discussion: The optimal frequency band for the detection of subclavian emboli is significantly higher than previous findings for the transcranial site. The duration output of the software can be used to estimate the size and the composition of emboli. Successful integration of the software into an ambulatory detection system may provide important site-specific bubble size distribution data for decompression modeling.
dc.language.isoeng
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectSosyal ve Beşeri Bilimler
dc.subjectSosyoloji
dc.subjectKlinik Tıp (MED)
dc.subjectSPOR BİLİMLERİ
dc.subjectKlinik Tıp
dc.subjectTIP, GENEL & İÇECEK
dc.subjectSosyal Bilimler (SOC)
dc.subjectSosyal Bilimler Genel
dc.subjectKAMU, ÇEVRE VE İŞ SAĞLIĞI
dc.titleAutomatic detection of bubbles in the subclavian vein using Doppler ultrasound signals
dc.typeMakale
dc.relation.journalAVIATION SPACE AND ENVIRONMENTAL MEDICINE
dc.contributor.department, ,
dc.identifier.volume77
dc.identifier.issue9
dc.identifier.startpage957
dc.identifier.endpage962
dc.contributor.firstauthorID179929


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record