dc.contributor.author | Bilmenoglu, Caglar | |
dc.contributor.author | Geckili, Onur | |
dc.contributor.author | Bilhan, Hakan | |
dc.contributor.author | Erdogan, Ozge | |
dc.contributor.author | Cilingir, Altug | |
dc.contributor.author | Kesoglu, Aysun Coskun | |
dc.contributor.author | Ozdiler, Arda | |
dc.date.accessioned | 2021-03-06T07:25:06Z | |
dc.date.available | 2021-03-06T07:25:06Z | |
dc.date.issued | 2015 | |
dc.identifier.citation | Geckili O., Cilingir A., Erdogan O., Kesoglu A. C. , Bilmenoglu C., Ozdiler A., Bilhan H., "The Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers", INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, cilt.30, ss.397-402, 2015 | |
dc.identifier.issn | 0882-2786 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_dc74ed45-ee32-409b-a55a-7bec0ffe9b24 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/145292 | |
dc.identifier.uri | https://doi.org/10.11607/jomi.3774 | |
dc.description.abstract | Purpose: The purpose of this study was to assess the influence of momentary retention forces on patient satisfaction and quality of life of two-implant-retained mandibular overdenture wearers. Materials and Methods: Edentulous patients who had been rehabilitated with two-implant-supported mandibular overdentures with single attachments and maxillary complete dentures at a university clinic were included in this study. The overdenture attachments were either ball or locator attachments. All the patients completed the Turkish version of the Oral Health Impact Profile-14 (OHIP-14) and the visual analog scale (VAS) satisfaction questionnaires. Momentary retention forces of the overdentures were measured using a custom-made dynamic testing machine. Results: Fifty-five patients were included in this study. No statistically significant association was detected between momentary retention forces and VAS scores (P > .05), but higher retention forces presented significantly better quality of life scores in the social disability and handicap domains of OHIP14 (P < .05). Conclusion: Within the limitations of this clinical study, it may be presumed that although higher instant retention force of an implant-retained overdenture provides better quality of life, it does not affect patient satisfaction. | |
dc.language.iso | eng | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Sağlık Bilimleri | |
dc.subject | DİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP | |
dc.subject | Klinik Tıp | |
dc.subject | Tıp | |
dc.subject | Diş Hekimliği | |
dc.title | The Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers | |
dc.type | Makale | |
dc.relation.journal | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS | |
dc.contributor.department | İstanbul Okan Üniversitesi , , | |
dc.identifier.volume | 30 | |
dc.identifier.issue | 2 | |
dc.identifier.startpage | 397 | |
dc.identifier.endpage | 402 | |
dc.contributor.firstauthorID | 73188 | |