Show simple item record

dc.contributor.authorAlhan, Cenk
dc.contributor.authorOncu-Davas, Seda
dc.date.accessioned2021-03-02T22:31:34Z
dc.date.available2021-03-02T22:31:34Z
dc.identifier.citationAlhan C., Oncu-Davas S., "Performance limits of seismically isolated buildings under near-field earthquakes", ENGINEERING STRUCTURES, cilt.116, ss.83-94, 2016
dc.identifier.issn0141-0296
dc.identifier.othervv_1032021
dc.identifier.otherav_0d31e73f-114d-4944-afb7-f75149bc6137
dc.identifier.urihttp://hdl.handle.net/20.500.12627/14480
dc.identifier.urihttps://doi.org/10.1016/j.engstruct.2016.02.043
dc.description.abstractThe mission of seismic isolation is two folds: (i) protecting the integrity and (ii) protecting the contents of a structure by reducing floor accelerations to target limits and concurrently keeping base displacements below practical and economical limits. To this end, while seismic isolation has proven to be successful under far-field earthquakes, its success in case of near-field earthquakes is being questioned for over a decade now; the main reason being the threat of excessive base displacements due to the presence of long period large velocity pulses. Lowering isolation period and increasing isolation damping aiming to reduce base displacements unfortunately may result in a reduced seismic performance in terms of floor accelerations particularly under far-field earthquakes. And the success level of such a precaution under near-field earthquakes depends both on the fault-distance and the pulse period to the isolation period ratio. Thus, the aim of this study is to evaluate the performance limits of buildings equipped with seismic isolation systems of different characteristics when subjected to near-field ground motions at different fault distances with different velocity pulse periods. Accordingly, a methodology for assessing the performance limit of a seismic isolation system design that explicitly considers the seismic actions on the contents of the superstructure in the near-field region is introduced. Benchmark buildings with base isolation systems of different isolation periods and characteristic force ratios are subjected to synthetically developed near-field earthquake records at different fault-distances with different velocity pulse periods and their seismic performances are reported. (C) 2016 Elsevier Ltd. All rights reserved.
dc.language.isoeng
dc.subjectMÜHENDİSLİK, SİVİL
dc.subjectMühendislik ve Teknoloji
dc.subjectİnşaat Mühendisliği
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.titlePerformance limits of seismically isolated buildings under near-field earthquakes
dc.typeMakale
dc.relation.journalENGINEERING STRUCTURES
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume116
dc.identifier.startpage83
dc.identifier.endpage94
dc.contributor.firstauthorID84977