Show simple item record

dc.contributor.authorUlu, Sevgi
dc.date.accessioned2021-03-05T21:42:52Z
dc.date.available2021-03-05T21:42:52Z
dc.date.issued2012
dc.identifier.citationUlu S., "SENSITIVE HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR DETERMINATION OF ATOMOXETINE IN PLASMA AND URINE PRECOLUMN DERIVATIZATION WITH 1-DIMETHYLAMINONAPHTHALENE-5-SULPHONYL CHLORIDE", JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, cilt.35, ss.747-756, 2012
dc.identifier.issn1082-6076
dc.identifier.otherav_da416203-fbf0-429d-8048-8b50c5b3ddd9
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/143884
dc.identifier.urihttps://doi.org/10.1080/10826076.2011.608232
dc.description.abstractA new and sensitive method was developed for the determination of atomoxetine in human plasma and urine using a reversed phase separation followed by pre-column derivatization with 1-dimethylaminonaphthalene-5-sulphonyl chloride (dansyl chloride) and fluorescence detection. The liquid chromatographic separation was achieved on a Inertsil C-18 column using methanol:water (85:15 v/v) as a mobile phase in an isocratic elution mode. The eluents were monitored by a fluorescence detector set at 375 and 537 nm of excitation and emission wavelengths, respectively. Mexiletine was used as an internal standard. The method was validated for linearity, limit of detection, limit of quantification, precision, accuracy, recovery, robustness, and system suitability. The method was linear over the concentration range of 10-2250 and 25-3000 ng mL(-1) for plasma and urine, respectively. The mean recovery of atomoxetine from plasma and urine was 97.39 and 96.77%, respectively.
dc.language.isoeng
dc.subjectAnalitik Kimya
dc.subjectSitogenetik
dc.subjectMoleküler Biyoloji ve Genetik
dc.subjectYaşam Bilimleri
dc.subjectBiyokimya
dc.subjectKİMYA, ANALİTİK
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectBiyoloji ve Biyokimya
dc.subjectBİYOKİMYASAL ARAŞTIRMA YÖNTEMLERİ
dc.subjectKimya
dc.subjectTemel Bilimler (SCI)
dc.subjectBİYOKİMYA VE MOLEKÜLER BİYOLOJİ
dc.subjectMoleküler Biyoloji ve Genetik
dc.subjectTıp
dc.subjectTemel Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTemel Bilimler
dc.titleSENSITIVE HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR DETERMINATION OF ATOMOXETINE IN PLASMA AND URINE PRECOLUMN DERIVATIZATION WITH 1-DIMETHYLAMINONAPHTHALENE-5-SULPHONYL CHLORIDE
dc.typeMakale
dc.relation.journalJOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES
dc.contributor.departmentİstanbul Üniversitesi , Eczacılık Fak: , Temel Bilimler
dc.identifier.volume35
dc.identifier.issue6
dc.identifier.startpage747
dc.identifier.endpage756
dc.contributor.firstauthorID61773


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record