Basit öğe kaydını göster

dc.contributor.authorAcun, Hediye
dc.contributor.authorKemikler, Gonul
dc.contributor.authorZubaroglu, Ali
dc.contributor.authorBOZKURT, AHMET
dc.date.accessioned2021-03-02T22:26:01Z
dc.date.available2021-03-02T22:26:01Z
dc.date.issued2014
dc.identifier.citationAcun H., Zubaroglu A., Kemikler G., BOZKURT A., "A comparative study of the peripheral doses from a linear accelerator with a multileaf collimator system", RADIATION PROTECTION DOSIMETRY, cilt.158, sa.3, ss.299-306, 2014
dc.identifier.issn0144-8420
dc.identifier.otherav_0c9fb5a5-1a82-4530-9ab0-5ebef348447b
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/14130
dc.identifier.urihttps://doi.org/10.1093/rpd/nct225
dc.description.abstractThis study presents a comparison of peripheral doses (PDs) measured using an ionisation chamber with treatment planning system (TPS) data and a Monte Carlo (MC) simulation of a 6-MV photon beam. The ion chamber measurements and MC simulation produced similar results for all out-of-field distances and field sizes considered in this study. For the 0 and 90 collimation angles, the average local per cent dose differences between the MC and TPS calculations were 2.7 (range: 2.4, 22.6) and 1.7 (range: 12.2, 10.8), respectively. The corresponding differences between the MC calculations and the ion chamber measurements were 2.2 (range: 2.4, 24.7) and 1.8 (range: 17, 15.2) for all field sizes and depths, respectively. Whereas the PDs increased with field sizes, the variations with depth were negligible at large distances. The TPS calculations usually yielded higher PDs than ion chamber measurements at distances close to the field edge. In contrast, at the farther distances, the TPS results indicated lower doses than both the ion chamber and the MC data. TPS data are not sufficient for use in calculating the out-of-field doses. These results can be used to estimate non-target organ doses to patients.
dc.language.isoeng
dc.subjectTıp
dc.subjectÇEVRE BİLİMLERİ
dc.subjectÇevre / Ekoloji
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectNükleer Tıp
dc.subjectSosyal ve Beşeri Bilimler
dc.subjectSosyoloji
dc.subjectTarımsal Bilimler
dc.subjectÇevre Mühendisliği
dc.subjectNükleer Fizik
dc.subjectTemel Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectKAMU, ÇEVRE VE İŞ SAĞLIĞI
dc.subjectSosyal Bilimler Genel
dc.subjectSosyal Bilimler (SOC)
dc.subjectNÜKLEAR BİLİMİ VE TEKNOLOJİSİ
dc.subjectFizik
dc.subjectTemel Bilimler (SCI)
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.titleA comparative study of the peripheral doses from a linear accelerator with a multileaf collimator system
dc.typeMakale
dc.relation.journalRADIATION PROTECTION DOSIMETRY
dc.contributor.departmentHarran Üniversitesi , ,
dc.identifier.volume158
dc.identifier.issue3
dc.identifier.startpage299
dc.identifier.endpage306
dc.contributor.firstauthorID213259


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster