Show simple item record

dc.contributor.authorGuven, Koray
dc.contributor.authorKadioglu, Teoman Cem
dc.contributor.authorPoyanli, Arzu
dc.contributor.authorBakir, Barış
dc.contributor.authorSalmaslioglu, Artuer
dc.date.accessioned2021-03-05T20:46:34Z
dc.date.available2021-03-05T20:46:34Z
dc.date.issued2009
dc.identifier.citationBakir B., Salmaslioglu A., Guven K., Poyanli A., Kadioglu T. C. , "Diffusion-Weighted MR Imaging in the Differential Diagnosis of Adrenal Adenomas and Nonadenomatous Adrenal Masses", TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, cilt.29, ss.1191-1197, 2009
dc.identifier.issn1300-0292
dc.identifier.othervv_1032021
dc.identifier.otherav_d5c057d1-60b0-4b3e-94ea-21ae12225208
dc.identifier.urihttp://hdl.handle.net/20.500.12627/141047
dc.description.abstractObjective: The aim of our study was to demonstrate the feasibility of body diffusion-weighted magnetic resonance (DW MR) imaging in the differential diagnosis of adrenal adenomas and non-adenomatous adrenal masses. Material and Methods: Thirty-seven adrenal masses in 32 consecutive patients (18 women, 14 men) were included in this prospective study. Of all the masses, 21 were adenomas and 16 were non-adenomatous adrenal masses. DW MR images were obtained by a body coil using a multisection single-shot echo planar sequence on the axial plane without breath holding (water excitation with b value of 50, 400 and 800 s/mm(2)). Signal intensities of the adenomas and non-adenomatous masses were measured for each b factor of 400 and 800 s/mm(2) using a region of interest (ROI). In addition, the signal intensities for apparent diffusion coefficient (ADC) calculation were measured. Mann Whitney U Test was used to compare signal intensities for each b factor (400 and 800 s/mm(2)) and for ADC values between the adenomas and non-adenomatous masses. Results: No significant difference was noted (p > 0.05) for ADC values between the two groups. Similarly, signal intensities with b factors of 400 and 800 s/mm(2) did not demonstrate a significant difference (p > 0.05) between the groups. Conclusion: DW MR imaging is not an effective method in the differential diagnosis of adenomatous and non-adenomatous lesions in adrenal glands.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectTIP, GENEL & İÇECEK
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTemel Tıp Bilimleri
dc.titleDiffusion-Weighted MR Imaging in the Differential Diagnosis of Adrenal Adenomas and Nonadenomatous Adrenal Masses
dc.typeMakale
dc.relation.journalTURKIYE KLINIKLERI TIP BILIMLERI DERGISI
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume29
dc.identifier.issue5
dc.identifier.startpage1191
dc.identifier.endpage1197
dc.contributor.firstauthorID73666


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record