Show simple item record

dc.contributor.authorDemir, Ahmet
dc.contributor.authorKaplan, Suleyman
dc.contributor.authorAktas, Abit
dc.contributor.authorTemel, Yasin
dc.contributor.authorYildirim, Mehmet
dc.contributor.authorAyyildiz, Mustafa
dc.contributor.authorVlamings, Rinkse
dc.contributor.authorAcar, Murat
dc.contributor.authorSimsek, Tekin
dc.date.accessioned2021-03-05T19:45:34Z
dc.date.available2021-03-05T19:45:34Z
dc.date.issued2014
dc.identifier.citationDemir A., Simsek T., Acar M., Aktas A., Vlamings R., Ayyildiz M., Yildirim M., Temel Y., Kaplan S., "Comparison between Flexible Collagen and Vein Conduits Used for Size-Discrepant Nerve Repair: An Experimental Study in Rats", JOURNAL OF RECONSTRUCTIVE MICROSURGERY, cilt.30, ss.329-334, 2014
dc.identifier.issn0743-684X
dc.identifier.othervv_1032021
dc.identifier.otherav_d0c4fcb6-19e1-4c37-8ccc-e0ff646a4bc9
dc.identifier.urihttp://hdl.handle.net/20.500.12627/138005
dc.identifier.urihttps://doi.org/10.1055/s-0033-1356551
dc.description.abstractPrimary nerve repair is the gold standard in nerve reconstruction. When primary repair is not possible for injured nerves, conduit-assisted repair methods are frequently used. As conduits, autologous vein segments or allogenic biodegradable products can be used. However, their effectiveness when used in a nerve defect where a size discrepancy exists has not been compared. In this study, either a vein graft or a synthetic collagen conduit was used to bridge 10-mm defects between size-discrepant tibial and peroneal nerves in a rat model. After 90 days, nerve regeneration was evaluated using electrophysiological and histological methods. It can be concluded based on the results of this study that bridging a 10-mm nerve gap with synthetic collagen conduits and autologous vein grafts yielded similar results in small-to-large nerve coaptations, with the vein graft being slightly more effective.
dc.language.isoeng
dc.subjectCERRAHİ
dc.subjectCerrahi Tıp Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectSağlık Bilimleri
dc.titleComparison between Flexible Collagen and Vein Conduits Used for Size-Discrepant Nerve Repair: An Experimental Study in Rats
dc.typeMakale
dc.relation.journalJOURNAL OF RECONSTRUCTIVE MICROSURGERY
dc.contributor.departmentOndokuz Mayıs Üniversitesi , ,
dc.identifier.volume30
dc.identifier.issue5
dc.identifier.startpage329
dc.identifier.endpage334
dc.contributor.firstauthorID67836


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record