Basit öğe kaydını göster

dc.contributor.authorFiratli, Sonmez
dc.contributor.authorTuna, Elif Bahar
dc.contributor.authorFiratli, Erhan
dc.contributor.authorOzel, Emre
dc.date.accessioned2021-03-05T16:55:22Z
dc.date.available2021-03-05T16:55:22Z
dc.date.issued2016
dc.identifier.citationOzel E., Tuna E. B. , Firatli S., Firatli E., "Comparison of total-etch, self-etch, and selective etching techniques on class V composite restorations prepared by Er:YAG laser and bur: a scanning electron microscopy study", MICROSCOPY RESEARCH AND TECHNIQUE, cilt.79, ss.998-1004, 2016
dc.identifier.issn1059-910X
dc.identifier.othervv_1032021
dc.identifier.otherav_c2f68993-5d3c-4e4a-9332-1b44e48e8830
dc.identifier.urihttp://hdl.handle.net/20.500.12627/129395
dc.identifier.urihttps://doi.org/10.1002/jemt.22735
dc.description.abstractThe purpose of this study was to compare total-etch, self-etch, and selective etching techniques on the marginal microleakage of Class V composite restorations prepared by Er:YAG laser and bur. Class V cavities prepared on both buccal and lingual surfaces of 30 premolars by Er:YAG laser or bur and divided into six groups. The occlusal margins were in enamel, and the cervical margins were in cementum. Group-1: bur preparation(bp)+Adper Single Bond 2 (ASB) +Filtek Z550 (FZ); Group-2: laser preparation(lp)+(ASB)+(FZ); Group-3: bp+Clearfil S3 Bond Plus (CSBP)+(FZ); Group-4: lp+(CSBP) (FZ); Group-5: bp+acid etching+(CSBP)+(FZ); Group-6: lp+acid etching+ (CSBP) +(FZ). All teeth were stored in distilled water at 37 degrees C for 24 hr, and then thermocycled 1000 times (5-55 degrees C). Five teeth from each group were chosen for the microleakage investigation, and two teeth for the scanning electron microscope evaluation. Teeth which were prepared for the microleakage test were immersed in .5% methylene blue dye for 24 hr. After immersion, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed using Kruskal-Wallis and Mann-Whitney U tests (p. 05). No significant differences were observed among any groups in terms of occlusal and cervical surfaces, separately (p>. 05). Different etching techniques did not influence microleakage of Class V restorations prepared by Er: YAG laser and bur.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectANATOMİ VE MORFOLOJİ
dc.subjectBiyoloji ve Biyokimya
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectAnatomi
dc.subjectBiyokimya
dc.subjectTıbbi Biyoloji
dc.subjectYaşam Bilimleri
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectBİYOLOJİ
dc.subjectMİKROSKOPİ
dc.subjectMikrobiyoloji
dc.titleComparison of total-etch, self-etch, and selective etching techniques on class V composite restorations prepared by Er:YAG laser and bur: a scanning electron microscopy study
dc.typeMakale
dc.relation.journalMICROSCOPY RESEARCH AND TECHNIQUE
dc.contributor.departmentKocaeli Üniversitesi , ,
dc.identifier.volume79
dc.identifier.issue10
dc.identifier.startpage998
dc.identifier.endpage1004
dc.contributor.firstauthorID37083


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster