Show simple item record

dc.contributor.authorUezer, Aysem
dc.contributor.authorErcag, Erol
dc.contributor.authorApak, Resat
dc.date.accessioned2021-03-05T16:06:43Z
dc.date.available2021-03-05T16:06:43Z
dc.date.issued2009
dc.identifier.citationErcag E., Uezer A., Apak R., "Selective spectro photometric determination of TNT using a dicyclohexylamine-based colorimetric sensor", TALANTA, cilt.78, ss.772-780, 2009
dc.identifier.issn0039-9140
dc.identifier.otherav_bf13f02a-5315-4e3c-9e49-db6f9eb8b3a9
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/126880
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2008.12.042
dc.description.abstractBecause of the extremely heterogeneous distribution of explosives in contaminated soils, on-site colorimetiic methods are efficient tools to assess the nature and extent of contamination. To meet the need for rapid and low-cost chemical sensing of explosive traces or residues in soil and post-blast debris, a colorimetric absorption-based sensor for trinitrotoluene (TNT) determination has been developed. The charge-transfer (CT) reagent (dicyclohexylamine, DCHA) is entrapped in a polyvinylchloride (PVC) polymer matrix plasticised with dioctylphtalate (DOP), and moulded into a transparent sensor membrane sliced into test Strips capable of sensing TNT showing an absorption maximum at 530 nm when placed in a 1-mm spectrophotometer cell. The sensor gave a linear absorption response to 5-50 ring L-1 TNT solutions in 30% aqueous acetone with limit of detection (LOD): 3 mg L-1 . The sensor is only affected by telryl, but not by RDX, pentaerythritoltetranitrate (PETN), dinitrotoluene (DNT), and picric acid. The Proposed method was statistically validated for TNT assay against high Performance liquid chromatography (HPLC) using a standard sample of Comp B. The developed sensor was relatively resistant to air and water, was of low-cost and high specificity, gave a rapid and reproducible response, and Was Suitable for field use of TNT determination in both dry and humid soil and groundwater With a portable colorimeter. (C) 2008 Elsevier B.V. All rights reserved.
dc.language.isoeng
dc.subjectTemel Bilimler (SCI)
dc.subjectTemel Bilimler
dc.subjectKİMYA, ANALİTİK
dc.subjectKimya
dc.subjectAnalitik Kimya
dc.titleSelective spectro photometric determination of TNT using a dicyclohexylamine-based colorimetric sensor
dc.typeMakale
dc.relation.journalTALANTA
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume78
dc.identifier.issue3
dc.identifier.startpage772
dc.identifier.endpage780
dc.contributor.firstauthorID23503


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record