Basit öğe kaydını göster

dc.contributor.authorBoz, Ismail
dc.contributor.authorKoc, Serkan Naci
dc.contributor.authorCetintas, Gamze
dc.contributor.authorGulce, Handan
dc.contributor.authorFilik, Hayati
dc.date.accessioned2021-03-05T15:55:22Z
dc.date.available2021-03-05T15:55:22Z
dc.date.issued2014
dc.identifier.citationFilik H., Cetintas G., Koc S. N. , Gulce H., Boz I., "Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol", RUSSIAN JOURNAL OF ELECTROCHEMISTRY, cilt.50, ss.243-252, 2014
dc.identifier.issn1023-1935
dc.identifier.othervv_1032021
dc.identifier.otherav_be2037b7-a628-4d88-8959-bcb2e31b11c9
dc.identifier.urihttp://hdl.handle.net/20.500.12627/126292
dc.identifier.urihttps://doi.org/10.1134/s1023193514030069
dc.description.abstractA Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop -casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5-200-M with differential pulse voltammetry (DPV) and the detection limit was 0.051-M. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determi- nation of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations.
dc.language.isoeng
dc.subjectFizikokimya
dc.subjectKimya
dc.subjectTemel Bilimler (SCI)
dc.subjectElektrokimya
dc.subjectTemel Bilimler
dc.subjectELEKTROKİMYA
dc.titleNafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol
dc.typeMakale
dc.relation.journalRUSSIAN JOURNAL OF ELECTROCHEMISTRY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume50
dc.identifier.issue3
dc.identifier.startpage243
dc.identifier.endpage252
dc.contributor.firstauthorID15568


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster