dc.contributor.author | Boz, Ismail | |
dc.contributor.author | Koc, Serkan Naci | |
dc.contributor.author | Cetintas, Gamze | |
dc.contributor.author | Gulce, Handan | |
dc.contributor.author | Filik, Hayati | |
dc.date.accessioned | 2021-03-05T15:55:22Z | |
dc.date.available | 2021-03-05T15:55:22Z | |
dc.date.issued | 2014 | |
dc.identifier.citation | Filik H., Cetintas G., Koc S. N. , Gulce H., Boz I., "Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol", RUSSIAN JOURNAL OF ELECTROCHEMISTRY, cilt.50, ss.243-252, 2014 | |
dc.identifier.issn | 1023-1935 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_be2037b7-a628-4d88-8959-bcb2e31b11c9 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/126292 | |
dc.identifier.uri | https://doi.org/10.1134/s1023193514030069 | |
dc.description.abstract | A Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop -casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5-200-M with differential pulse voltammetry (DPV) and the detection limit was 0.051-M. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determi- nation of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations. | |
dc.language.iso | eng | |
dc.subject | Fizikokimya | |
dc.subject | Kimya | |
dc.subject | Temel Bilimler (SCI) | |
dc.subject | Elektrokimya | |
dc.subject | Temel Bilimler | |
dc.subject | ELEKTROKİMYA | |
dc.title | Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol | |
dc.type | Makale | |
dc.relation.journal | RUSSIAN JOURNAL OF ELECTROCHEMISTRY | |
dc.contributor.department | İstanbul Üniversitesi , , | |
dc.identifier.volume | 50 | |
dc.identifier.issue | 3 | |
dc.identifier.startpage | 243 | |
dc.identifier.endpage | 252 | |
dc.contributor.firstauthorID | 15568 | |