Basit öğe kaydını göster

dc.contributor.authorGeckili, Onur
dc.contributor.authorSulun, Tonguc
dc.contributor.authorBilgin, Tayfun
dc.contributor.authorBilhan, Hakan
dc.date.accessioned2021-03-05T15:52:33Z
dc.date.available2021-03-05T15:52:33Z
dc.identifier.citationBilhan H., Geckili O., Sulun T., Bilgin T., "A Quality-of-Life Comparison Between Self-Aligning and Ball Attachment Systems for 2-Implant-Retained Mandibular Overdentures", JOURNAL OF ORAL IMPLANTOLOGY, cilt.37, ss.167-173, 2011
dc.identifier.issn0160-6972
dc.identifier.othervv_1032021
dc.identifier.otherav_bdf5f37f-9c43-4ec0-862a-36fc0c30d2a3
dc.identifier.urihttp://hdl.handle.net/20.500.12627/126193
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-d-10-00070
dc.description.abstractThe aim of this study was to evaluate the self-aligning overdenture attachment system by comparing its oral health related quality of life (OHRQL) with a traditionally used ball attachment system. In this randomized, within-subject crossover trial, 25 edentulous subjects each received 2 mandibular implants, and were then assigned to receive either self-aligning or traditional ball attachments. After 3 months, all subjects were switched to the second attachment type. The OHRQL was evaluated for both of the treatments using the short form of the Oral Health Impact Profile (OHIP-14). A subanalysis among subjects with below-average space available for attachment placement was also performed. Wilcoxon signed-rank test was used to compare differences between groups. Scores on the OHIP-14 physical disability domain were significantly better for the self-aligning attachment system (P = .049). Among subjects with below-average attachment space, functional limitation, psychological discomfort, physical disability, psychological disability, and total OHIP-14, scores were significantly better for the self-aligning attachment system (P = .041, P = .047, P = .048, P = .026, and P = .005, respectively). The self-aligning attachment system for 2-implant-retained mandibular overdentures is equal or superior to traditional ball attachments in all domains of the OHIP-14.
dc.language.isoeng
dc.subjectDiş Hekimliği
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleA Quality-of-Life Comparison Between Self-Aligning and Ball Attachment Systems for 2-Implant-Retained Mandibular Overdentures
dc.typeMakale
dc.relation.journalJOURNAL OF ORAL IMPLANTOLOGY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume37
dc.identifier.startpage167
dc.identifier.endpage173
dc.contributor.firstauthorID28118


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster