dc.contributor.author | Geckili, Onur | |
dc.contributor.author | Sulun, Tonguc | |
dc.contributor.author | Bilgin, Tayfun | |
dc.contributor.author | Bilhan, Hakan | |
dc.date.accessioned | 2021-03-05T15:52:33Z | |
dc.date.available | 2021-03-05T15:52:33Z | |
dc.identifier.citation | Bilhan H., Geckili O., Sulun T., Bilgin T., "A Quality-of-Life Comparison Between Self-Aligning and Ball Attachment Systems for 2-Implant-Retained Mandibular Overdentures", JOURNAL OF ORAL IMPLANTOLOGY, cilt.37, ss.167-173, 2011 | |
dc.identifier.issn | 0160-6972 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_bdf5f37f-9c43-4ec0-862a-36fc0c30d2a3 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/126193 | |
dc.identifier.uri | https://doi.org/10.1563/aaid-joi-d-10-00070 | |
dc.description.abstract | The aim of this study was to evaluate the self-aligning overdenture attachment system by comparing its oral health related quality of life (OHRQL) with a traditionally used ball attachment system. In this randomized, within-subject crossover trial, 25 edentulous subjects each received 2 mandibular implants, and were then assigned to receive either self-aligning or traditional ball attachments. After 3 months, all subjects were switched to the second attachment type. The OHRQL was evaluated for both of the treatments using the short form of the Oral Health Impact Profile (OHIP-14). A subanalysis among subjects with below-average space available for attachment placement was also performed. Wilcoxon signed-rank test was used to compare differences between groups. Scores on the OHIP-14 physical disability domain were significantly better for the self-aligning attachment system (P = .049). Among subjects with below-average attachment space, functional limitation, psychological discomfort, physical disability, psychological disability, and total OHIP-14, scores were significantly better for the self-aligning attachment system (P = .041, P = .047, P = .048, P = .026, and P = .005, respectively). The self-aligning attachment system for 2-implant-retained mandibular overdentures is equal or superior to traditional ball attachments in all domains of the OHIP-14. | |
dc.language.iso | eng | |
dc.subject | Diş Hekimliği | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Tıp | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Klinik Tıp | |
dc.subject | DİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP | |
dc.title | A Quality-of-Life Comparison Between Self-Aligning and Ball Attachment Systems for 2-Implant-Retained Mandibular Overdentures | |
dc.type | Makale | |
dc.relation.journal | JOURNAL OF ORAL IMPLANTOLOGY | |
dc.contributor.department | İstanbul Üniversitesi , , | |
dc.identifier.volume | 37 | |
dc.identifier.startpage | 167 | |
dc.identifier.endpage | 173 | |
dc.contributor.firstauthorID | 28118 | |