Basit öğe kaydını göster

dc.contributor.authorGunduz, Mehmet Can
dc.contributor.authorBingol, Enver Baris
dc.contributor.authorCetin, Omer
dc.contributor.authorKasikci, Guven
dc.date.accessioned2021-03-05T11:39:25Z
dc.date.available2021-03-05T11:39:25Z
dc.date.issued2012
dc.identifier.citationKasikci G., Cetin O., Bingol E. B. , Gunduz M. C. , "Relations between electrical conductivity, somatic cell count, California mastitis test and some quality parameters in the diagnosis of subclinical mastitis in dairy cows", TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES, cilt.36, ss.49-55, 2012
dc.identifier.issn1300-0128
dc.identifier.otherav_a940662d-fd1e-41ae-9710-005e84e4bef7
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/113061
dc.identifier.urihttps://doi.org/10.3906/vet-1103-4
dc.description.abstractThis study was conducted to determine the effectiveness of the electrical conductivity (EC) method on the diagnosis of subclinical mastitis in dairy cows comparing with somatic cell count (SCC) and California mastitis test (CMT), and also to investigate the effect of these values on the amount of total viable bacteria, density, freezing point, and mineral substances. A total of 386 milk samples collected from quarters of 188 cows at 10 different farms were used as materials. Of the samples, 258 (66.85%) were CMT (+), 85 (22.02%) were CMT (++), and 43 (11.13%) were CMT (+++). The mean EC and SCC were 25.71, 28.02, and 29.63 mS and 249,453, 1,167,058, and 2,108,139, respectively, according to the CMT results. The total viable bacteria counts ranged from 3.4771 to 6.9395, from 3.4771 to 7.3617, and from 4.7782 to 7.5315 log CFU/mL, respectively. The average amounts of mineral substances were 0.65%, 0.70%, and 0.76%; the density values were 1.031, 1.0297, and 1.029; and the freezing points were -0.5281, -0.5285, and -0.5282, respectively. As a result, it has been concluded that EC showed similarity with the CMT and the SCC in the detection of subclinical mastitis; furthermore, its reliability would further increase when used together with the other diagnostic methods.
dc.language.isoeng
dc.subjectTarım ve Çevre Bilimleri (AGE)
dc.subjectVeteriner Bilimleri
dc.subjectVETERİNERLİK BİLİMLERİ
dc.subjectBitki ve Hayvan Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTarımsal Bilimler
dc.titleRelations between electrical conductivity, somatic cell count, California mastitis test and some quality parameters in the diagnosis of subclinical mastitis in dairy cows
dc.typeMakale
dc.relation.journalTURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume36
dc.identifier.issue1
dc.identifier.startpage49
dc.identifier.endpage55
dc.contributor.firstauthorID49391


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster