Basit öğe kaydını göster

dc.contributor.authorKIZILKAYA, MELDA
dc.contributor.authorArslan, Osman Şevki
dc.contributor.authorÖZKAN, ŞEHİRBAY
dc.contributor.authorIskeleli, G
dc.date.accessioned2021-03-05T11:39:17Z
dc.date.available2021-03-05T11:39:17Z
dc.date.issued2002
dc.identifier.citationIskeleli G., KIZILKAYA M., Arslan O. Ş. , ÖZKAN Ş., "The effect of artificial tears on corneal surface regularity in patients with Sjogren syndrome", OPHTHALMOLOGICA, cilt.216, ss.118-122, 2002
dc.identifier.issn0030-3755
dc.identifier.otherav_a93d4dcf-e93c-4472-91b3-2809d2ad394d
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/113052
dc.identifier.urihttps://doi.org/10.1159/000048310
dc.description.abstractPurpose: To evaluate the effect of artificial tears on the topographic parameters associated with corneal surface regularity in patients with Sjogren syndrome. Methods: A total of 38 eyes of 20 patients with Sjogren syndrome were evaluated prospectively. The mean age of the patients was 50.5 +/- 15.3 years (range, 28-76). Corneal topography with the Topographic Modeling System (TMS-2, Tomey) was performed before and after the instillation of artificial tears. The surface regularity index (SRI), surface asymmetry index (SAI), potential visual acuity (PVA) and mean astigmatism were compared in dry eyes before and after the instillation of artificial tears. Results: Before the instillation of artificial tears SAI, SRI, PVA and mean antigmatism values were found to be 1.37 +/- 1.47, 0.74 +/- 0.42, 20/30.92 +/- 20/8.12 and 1.53 +/- 1.47 D, respectively. In corneal topography performed after the instillation of artificial tears SAI, SRI, PVA and mean astigmatism values were 0.71 +/- 0.82, 0.43 +/- 0.36, 20/25.92 +/- 20/5.55 and 1.08 +/- 1.18, respectively. When compared statistically, the SRI, SAI, and mean astigmatism all decreased significantly and the PVA improved (p = 0.0001). Conclusion: Irregular corneal surface in dry eye patients affects optical quality. The statistically significant improvement observed in SRI and SAI values after the instillation of artificial tears also improves the PVA that is especially related to SRI. Copyright (C) 2002 S. Karger AG, Basel.
dc.language.isoeng
dc.subjectGöz Hastalıkları ve Cerrahisi
dc.subjectCerrahi Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectOFTALMOLOJİ
dc.titleThe effect of artificial tears on corneal surface regularity in patients with Sjogren syndrome
dc.typeMakale
dc.relation.journalOPHTHALMOLOGICA
dc.contributor.department, ,
dc.identifier.volume216
dc.identifier.issue2
dc.identifier.startpage118
dc.identifier.endpage122
dc.contributor.firstauthorID18145


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster