dc.contributor.author | Ertas, Abdulselam | |
dc.contributor.author | Yilmaz, Pelin | |
dc.contributor.author | Kolak, Ufuk | |
dc.date.accessioned | 2021-03-05T11:33:41Z | |
dc.date.available | 2021-03-05T11:33:41Z | |
dc.date.issued | 2014 | |
dc.identifier.citation | Yilmaz P., Ertas A., Kolak U., "Simultaneous determination of seven phthalic acid esters in beverages using ultrasound and vortex-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography", JOURNAL OF SEPARATION SCIENCE, cilt.37, sa.16, ss.2111-2117, 2014 | |
dc.identifier.issn | 1615-9306 | |
dc.identifier.other | av_a8c7c532-8686-432b-bc87-a91563053bd1 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/112785 | |
dc.identifier.uri | https://doi.org/10.1002/jssc.201400408 | |
dc.description.abstract | A sensitive, rapid, and simple high-performance liquid chromatography with UV detection method was developed for the simultaneous determination of seven phthalic acid esters (dimethyl phthalate, dipropyl phthalate, di-n-butyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate, di-(2-ethylhexyl) phthalate, and di-n-octyl phthalate) in several kinds of beverage samples. Ultrasound and vortex-assisted dispersive liquid-liquid microextraction method was used. The separation was performed using an Intersil ODS-3 column (C-18, 250 x 4.6 mm, 5.0 mu m) and a gradient elution with a mobile phase consisting of MeOH/ACN (50: 50) and 0.2 M KH2PO4 buffer. Analytes were detected by a UV detector at 230 nm. The developed method was validated in terms of linearity, limit of detection, limit of quantification, repeatability, accuracy, and recovery. Calibration equations and correlation coefficients (>0.99) were calculated by least squares method with weighting factor. The limit of detection and quantification were in the range of 0.019-0.208 and 0.072-0.483 mu g/L. The repeatability and intermediate precision were determined in terms of relative standard deviation to be within 0.03-3.93 and 0.02-4.74%, respectively. The accuracy was found to be in the range of -14.55 to 15.57% in terms of relative error. Seventeen different beverage samples in plastic bottles were successfully analyzed, and ten of them were found to be contaminated by different phthalic acid esters. | |
dc.language.iso | eng | |
dc.subject | Temel Bilimler (SCI) | |
dc.subject | Temel Bilimler | |
dc.subject | KİMYA, ANALİTİK | |
dc.subject | Kimya | |
dc.subject | Analitik Kimya | |
dc.title | Simultaneous determination of seven phthalic acid esters in beverages using ultrasound and vortex-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography | |
dc.type | Makale | |
dc.relation.journal | JOURNAL OF SEPARATION SCIENCE | |
dc.contributor.department | Dicle Üniversitesi , , | |
dc.identifier.volume | 37 | |
dc.identifier.issue | 16 | |
dc.identifier.startpage | 2111 | |
dc.identifier.endpage | 2117 | |
dc.contributor.firstauthorID | 58985 | |