| dc.contributor.author | Aydar, Sevda | |
| dc.contributor.author | Avan, Asiye A. | |
| dc.contributor.author | Filik, Hayati | |
| dc.date.accessioned | 2021-03-05T10:47:44Z | |
| dc.date.available | 2021-03-05T10:47:44Z | |
| dc.date.issued | 2016 | |
| dc.identifier.citation | Filik H., Avan A. A. , Aydar S., "Voltammetric Sensing of Uremic Toxin Indoxyl Sulfate Using High Performance Disposable Screen-Printed Graphene Electrode", CURRENT PHARMACEUTICAL ANALYSIS, cilt.12, ss.36-42, 2016 | |
| dc.identifier.issn | 1573-4129 | |
| dc.identifier.other | av_a4fb6ceb-5d19-4565-b0fd-2dee7fe8cbd9 | |
| dc.identifier.other | vv_1032021 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.12627/110342 | |
| dc.identifier.uri | https://doi.org/10.2174/1573412911666150520000605 | |
| dc.description.abstract | We focused on a rapid method for the assay of protein unbound indoxyl sulfate (IS) in urine samples by square-wave voltammetry. A sensor based on the electroactivity of commercial graphene screen-printed electrode (GR-SPE) for sensitive estimation of uremic toxin indoxyl sulfate was presented. The behaviors of uremic solute indoxyl sulfate on GR-SP electrodes were explored by cyclic and square-wave voltammetry. The outcomes displayed that the GR-SP electrode exposed perfect electroactivity to uremic toxin indoxyl sulfate and the oxidation of uremic solute IS is a multi-step and irreversible process. The process is pH dependent and takes place with the forging of a main oxidation product that is adsorbed on the GR-SP electrode surface. The calibration curve was achieved in the IS concentration range of 0.5-80 mu M and the limit of detection was calculated to be 0.064 mu M at a signal-to-noise ratio of 3. The use of the commercially disposable GR-SPE in human serum and urine sample assays obtained satisfactory results, which made it a promising alternative in routine sensing applications. | |
| dc.language.iso | eng | |
| dc.subject | Yaşam Bilimleri | |
| dc.subject | Temel Bilimler | |
| dc.subject | Temel Eczacılık Bilimleri | |
| dc.subject | Eczacılık | |
| dc.subject | Sağlık Bilimleri | |
| dc.subject | Yaşam Bilimleri (LIFE) | |
| dc.subject | Farmakoloji ve Toksikoloji | |
| dc.subject | FARMAKOLOJİ VE ECZACILIK | |
| dc.title | Voltammetric Sensing of Uremic Toxin Indoxyl Sulfate Using High Performance Disposable Screen-Printed Graphene Electrode | |
| dc.type | Makale | |
| dc.relation.journal | CURRENT PHARMACEUTICAL ANALYSIS | |
| dc.contributor.department | İstanbul Üniversitesi , , | |
| dc.identifier.volume | 12 | |
| dc.identifier.issue | 1 | |
| dc.identifier.startpage | 36 | |
| dc.identifier.endpage | 42 | |
| dc.contributor.firstauthorID | 15592 | |