Show simple item record

dc.contributor.authorAydar, Sevda
dc.contributor.authorAvan, Asiye A.
dc.contributor.authorFilik, Hayati
dc.date.accessioned2021-03-05T10:47:44Z
dc.date.available2021-03-05T10:47:44Z
dc.date.issued2016
dc.identifier.citationFilik H., Avan A. A. , Aydar S., "Voltammetric Sensing of Uremic Toxin Indoxyl Sulfate Using High Performance Disposable Screen-Printed Graphene Electrode", CURRENT PHARMACEUTICAL ANALYSIS, cilt.12, ss.36-42, 2016
dc.identifier.issn1573-4129
dc.identifier.otherav_a4fb6ceb-5d19-4565-b0fd-2dee7fe8cbd9
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/110342
dc.identifier.urihttps://doi.org/10.2174/1573412911666150520000605
dc.description.abstractWe focused on a rapid method for the assay of protein unbound indoxyl sulfate (IS) in urine samples by square-wave voltammetry. A sensor based on the electroactivity of commercial graphene screen-printed electrode (GR-SPE) for sensitive estimation of uremic toxin indoxyl sulfate was presented. The behaviors of uremic solute indoxyl sulfate on GR-SP electrodes were explored by cyclic and square-wave voltammetry. The outcomes displayed that the GR-SP electrode exposed perfect electroactivity to uremic toxin indoxyl sulfate and the oxidation of uremic solute IS is a multi-step and irreversible process. The process is pH dependent and takes place with the forging of a main oxidation product that is adsorbed on the GR-SP electrode surface. The calibration curve was achieved in the IS concentration range of 0.5-80 mu M and the limit of detection was calculated to be 0.064 mu M at a signal-to-noise ratio of 3. The use of the commercially disposable GR-SPE in human serum and urine sample assays obtained satisfactory results, which made it a promising alternative in routine sensing applications.
dc.language.isoeng
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.subjectTemel Eczacılık Bilimleri
dc.subjectEczacılık
dc.subjectSağlık Bilimleri
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectFarmakoloji ve Toksikoloji
dc.subjectFARMAKOLOJİ VE ECZACILIK
dc.titleVoltammetric Sensing of Uremic Toxin Indoxyl Sulfate Using High Performance Disposable Screen-Printed Graphene Electrode
dc.typeMakale
dc.relation.journalCURRENT PHARMACEUTICAL ANALYSIS
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume12
dc.identifier.issue1
dc.identifier.startpage36
dc.identifier.endpage42
dc.contributor.firstauthorID15592