Show simple item record

dc.contributor.authorKURT, AYŞEGÜL
dc.contributor.authorGencel, Burc
dc.contributor.authorDayan, Suleyman Cagatay
dc.contributor.authorKiseri, Burim
dc.date.accessioned2021-03-05T09:01:02Z
dc.date.available2021-03-05T09:01:02Z
dc.date.issued2019
dc.identifier.citationDayan S. C. , Kiseri B., Gencel B., KURT A., "Evaluation of the Internal and Marginal Discrepancies of Co-Cr Metal Copings Prepared via CAD/CAM and Conventional Casting", EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, cilt.27, ss.26-31, 2019
dc.identifier.othervv_1032021
dc.identifier.otherav_9bd69112-b9a6-4c6e-80ba-1329dc243493
dc.identifier.urihttp://hdl.handle.net/20.500.12627/104764
dc.identifier.urihttps://doi.org/10.1922/ejprd_01865dayan06
dc.description.abstractThe aim of this study was to assess the internal and marginal discrepancies of chromium-cobalt (Co/Cr) copings fabricated using different techniques. A typodont molar tooth was prepared and replicated in die stone and scanned. Forty Co-Cr alloy copings were produced using four different production techniques: conventional casting (C-group), direct metal laser sintering (DMLS-group), micro-stereolithography/casting combination (mu SLA-group), and computer-aided milling (M-group) (n = 10). The internal and marginal discrepancies at various reference points were determined via digital microscopy. Analysis of variance (ANOVA) and Tukey's multiple comparisons tests were used for statistical analysis (p=0.05). The marginal and cervical discrepancies of the C-group were similar to those of the M-group (p>0.05) and better than those of the mu SLA-group (p<0.05). The marginal and internal discrepancies of all groups were within clinically acceptable limits, but further improvements in the mu SLA and DMLS techniques may be required prior to clinical implementation.
dc.language.isoeng
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectDiş Hekimliği
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleEvaluation of the Internal and Marginal Discrepancies of Co-Cr Metal Copings Prepared via CAD/CAM and Conventional Casting
dc.typeMakale
dc.relation.journalEUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY
dc.contributor.departmentUBT Coll , ,
dc.identifier.volume27
dc.identifier.issue1
dc.identifier.startpage26
dc.identifier.endpage31
dc.contributor.firstauthorID262970


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record