Basit öğe kaydını göster

dc.contributor.authorFirat, Zeynep
dc.contributor.authorBayram, ALİ
dc.contributor.authorKovanlikaya, Arzu
dc.contributor.authorUlug, Aziz Muefit
dc.contributor.authorKovanlikaya, Ilhami
dc.contributor.authorGurses, Bengi
dc.contributor.authorKabakci, Neslihan
dc.date.accessioned2021-03-05T07:39:48Z
dc.date.available2021-03-05T07:39:48Z
dc.date.issued2008
dc.identifier.citationGurses B., Kabakci N., Kovanlikaya A., Firat Z., Bayram A., Ulug A. M. , Kovanlikaya I., "Diffusion tensor imaging of the normal prostate at 3 Tesla", EUROPEAN RADIOLOGY, cilt.18, ss.716-721, 2008
dc.identifier.issn0938-7994
dc.identifier.otherav_94f045dd-f6a1-4782-9e5f-8904c1166b66
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/100315
dc.identifier.urihttps://doi.org/10.1007/s00330-007-0795-7
dc.description.abstractThe aim of this study was to assess the feasibility of diffusion tensor imaging (DTI) of the prostate and to determine normative fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of healthy prostate with a 3-Tesla magnetic resonance imaging (MRI) system. Thirty volunteers with a mean age of 28 (25-35) years were scanned with a 3-Tesla MRI (Intera Achieva; Philips, The Netherlands) system using a six-channel phased array coil. Initially, T2-weighted turbo spin-echo (TSE) axial images of the prostate were obtained. In two subjects, a millimetric hypointense signal change was detected in the peripheral zones on T2-weighted TSE images. These two subjects were excluded from the study. DTI with single-shot echo-planar imaging (ssEPI) was performed in the remaining 28 subjects. ADC and FA values were measured using the manufacturer supplied software by positioning 9-pixel ROIs on each zone. Differences between parameters of the central and peripheral zones were assessed. Mean ADC value of the central (1.220 +/- 0.271 x 10(-3) mm(2)/s) was found to be significantly lower when compared with the peripheral gland (1.610 +/- 0.347 x 10(-3) mm(2)/s) (P < 0.01). Mean FA of the central gland was significantly higher (0.26), compared with the peripheral gland (0.16) (P < 0.01). This study shows the feasibility of prostate DTI with a 3-Tesla MR system and the normative FA and ADC values of peripheral and central zones of the normal prostate. The results are compatible with the microstructural organization of the gland.
dc.language.isoeng
dc.subjectNükleer Tıp
dc.subjectDahili Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.titleDiffusion tensor imaging of the normal prostate at 3 Tesla
dc.typeMakale
dc.relation.journalEUROPEAN RADIOLOGY
dc.contributor.departmentYeditepe Üniversitesi , ,
dc.identifier.volume18
dc.identifier.issue4
dc.identifier.startpage716
dc.identifier.endpage721
dc.contributor.firstauthorID102774


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster