dc.contributor.author | Yaltırık, Mehmet | |
dc.date.accessioned | 2020-09-02T06:58:14Z | |
dc.date.available | 2020-09-02T06:58:14Z | |
dc.date.issued | 2003 | |
dc.identifier.citation | Yaltırık M., "Tru-Cut And Fine Needle Aspiration Biopsy Diagnosis Of Lesions Of The Jaws", Turk J Med Sci, Vol.33, Pp.249-253, 2003 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/1013 | |
dc.description.abstract | <p>Abstract: Nowadays, modern biopsy techniques such as fine and wide needles are used instead of invasive biopsy techniques for examining malign and benign lesions.</p>
<p>This study examines whether wide needle biopsy (Tru-cut) possesses advantages as an alternative method to open biopsy. This study was performed on 40 patients with suspicious intra-jaw lesions. An 18-gauge, three-piece biopsy device was used.</p>
<p>All the samples were sent to the tumor pathology unit at the oncology institute for histopathologic and cytopathologic examination. Thirty-seven of the 40 samples were adequate for diagnosis and three inadequate were.</p>
<p>When we considered the results of Tru-cut and fine needle biopsy, the diagnostic value increased to 62.5%.</p>
<p>In each lesion, the success rate of open biopsy is 92.5%, the success rate of Tru-cut biopsy is 55% and that of fine needle biopsy is 42.5%.</p>
<p>According to our results, if we can support the study of this technique with new studies and can improve the specific apparatus for the maxillo-facial region, this can be a good alternative technique for open biopsy applications.</p>
<p>Key Words: Biopsy, Tru-cut, Fine needle</p> | |
dc.language.iso | eng | |
dc.rights | Atıf 4.0 Uluslararası | |
dc.rights.uri | info:eu-repo/semantics/openAccess | |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Clinical Medicine (Med) | |
dc.title | Tru-Cut and Fine Needle Aspiration Biopsy Diagnosis of Lesions of the Jaws | |
dc.type | article | |
dc.contributor.department | Diş Hekimliği Fakültesi,Agız Diş Cene Cerrahisi | |
dc.contributor.authorID | 0000-0002-4044-3573 | |
dc.identifier.volume | 33 | |
dc.identifier.startpage | 249 | |
dc.identifier.endpage | 253 | |