• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Safety of a thermal vessel sealer on main pulmonary vessels

Tarih
2007
Yazar
AHISKALI, Rengin
YUKSEL, Mustafa
BATIREL, Hasan Fevzi
Ozer, Kürşat
Demirutku, Alper
LACIN, Tunc
Üst veri
Tüm öğe kaydını göster
Özet
Objective: LigaSure (Valleylab, Tyco Healthcare, Boulder, CO)is a novel instrument with widespread use in various surgical disciplines for vessel seating. It uses heat energy to denature collagen and elastin and achieve vessel seating. We investigated the safety of LigaSure in pulmonary arteries (PA) and veins (PV). Methods: Twelve sheep were anesthetized and endotracheally intubated. Six underwent right lower lobectomy (Group 1) and six right upper lobectomy (Group 2). All of the vessels in both groups were divided with LigaSure. Diameters of vessels were measured. Intraoperatively, pulmonary artery pressures (PAP) were monitored in Group 1. Following vascular division, ephedrine was injected to increase PAP in Group 1. In Group 2, animals were followed and euthanized at 7 days. Both immediate and 7 day samples were obtained from divided vessel stumps. Conventional histology was done. Statistical analysis was performed using t-test and Fisher's exact test. Results: Mean diameter of PAs (n = 9) divided in Group 1 was 8.3 mm (3-11) and of PVs (n = 8) was 10.4 mm (4-15). Mean PAP increased from 18 (27/9) to 27 (45/18) mmHg after ephedrine injection. Dehiscence rate was 2/6 in PAs and 3/6 in PVs larger than 9 mm in diameter. Mean diameter of PAs (n = 8) divided in Group 2 was 5.7 mm (3-7) and of PVs (n = 9) was 4.6 mm (4-6). No early or late (7 days) vascular disruption was seen in Group 2. Bleeding incidence was significantly different between groups (Fisher's exact test p = 0.015). Overall no dehiscence was observed in vessels less than 7 mm in diameter. Histology of intraoperative samples showed thermal injury and necrosis. Seven day samples showed short segment necrosis limited to the vessel watt, fibrosis, thrombus formation without inflammation, and minimal granulation tissue. Conclusions: LigaSure achieves perfect seating in pulmonary vessels less than 7 mm in diameter in sheep intra- and postoperatively even following a pressure challenge. It can safety be used in segmental branches of PAs and PVs during open or thoracoscopic surgery. (c) 2007 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Bağlantı
http://hdl.handle.net/20.500.12627/80003
https://doi.org/10.1016/j.ejcts.2006.11.038
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV