• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effects of different modes of ventilation and head position on the size of the vena jugularis interna

Yazar
Kaya, Guner
Koksal, Guniz M.
Erbabacan, Emre
Altindas, Fatiş
Ekici, Birsel
Üst veri
Tüm öğe kaydını göster
Özet
PURPOSE: Right internal jugular vein (RIJV) catheterisation is a common procedure in patients undergoing surgery. We aimed to compare diameters and the cross-sectional area (CSA) of the RIJV when the head is in a neutral or 30-degree rotated position during mechanical ventilation in various modes and spontaneous ventilation. METHODS: Thirty patients undergoing surgery were included in the study. In each patient, still ultrasound images of the vena jugularis interna were taken with the head in a neutral position and with the neck rotated 30 degrees to the left, first under spontaneous ventilation (group S), then after the induction of anaesthesia under volume-controlled ventilation (group V) and under pressure-controlled ventilation (group P). The six still images were evaluated in terms of transverse and anteroposterior diameters and CSA. RESULTS: Diameters in the neutral and lateral positions in group S were significantly smaller than in group P and group V (neutral transverse p = 0.01, anteroposterior p = 0.041, rotated transverse p = 0.01, anteroposterior p = 0.03). The CSAs of the RIJV in the neutral and lateral positions were significantly larger in group P and group V than Group S (lateral CSA p = 0.001, neutral CSA p = 0.002). CSA increased significantly only in group P when the head was rotated 30 degrees laterally (p = 0.002). CONCLUSION: We conclude that both pressure-controlled and volume-controlled mechanical ventilation have similar effects on the CSA and diameters of the RIJV. Positioning of the head with a 30-degree rotation laterally has different effects on CSA depending on the ventilation mode used. A neutral position should be preferred with spontaneous ventilation whereas 30 degree rotation should be preferred in patients under pressure-controlled and volume-controlled ventilation.
Bağlantı
http://hdl.handle.net/20.500.12627/75683
https://doi.org/10.4414/smw.2014.13946
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV