• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Reproducibility of technetium-99m ethylenedicysteine clearance

Tarih
1999
Yazar
Halac, M
Uslu, I
Ozcelik, N
Kabasakal, L
Alkan, E
Üst veri
Tüm öğe kaydını göster
Özet
It has been shown that technetium-99m ethylenedicysteine (Tc-99m-EC) clearance displays a strong correlation with orthoiodohippurate clearance and that it is possible to estimate effective renal plasma flow from Tc-99m-EC clearance. However, in routine practice, when monitoring renal function of patients by clearance determinations it is imperative to test the reproducibility of the clearance technique in order to decide whether the changes in renal function are related to disease or not. The aim of this study was to rest the reproducibility of Tc-99m-EC clearance. The study group comprised 13 patients aged between 24 and 58 years (eight female and five male). Two patients had single kidneys due to agenesis and hypoplasia. Plasma creatinine and BUN levels were within the normal range and remained stable between two clearance studies. None of the patients were receiving medication. Two Separate multiple sample clearance studies were performed in each patient within a week. The difference between two studies was expressed as a percentage of the mean value of the two studies, and the standard deviation of these percentages represented the precision. The plasma clearance of Tc-99m-EC in the first-step studies ranged from 190 ml/min to 561 ml/min with a mean of 411+/-101 ml/min. The clearances obtained from the second-step studies ranged from 248 ml/min to 552 ml/min, with a mean of 387+/-94 ml/min. There was no statistically significant difference between the two clearance studies (P>0.05). There was a mean difference of 5.3% between the first and second clearance studies, and the precision was found to be 12.7%. In conclusion, this study suggested that consecutive Tc-99m-EC clearance measurements should be interpreted cautiously.
Bağlantı
http://hdl.handle.net/20.500.12627/68649
https://doi.org/10.1007/s002590050465
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV